0
Research Papers

Absolute radiometric calibration of the KOMPSAT-2 multispectral camera using a reflectance-based method and empirical comparison with IKONOS and QuickBird images

[+] Author Affiliations
Sungu Lee

Korea Aerospace Research Institute, 45 Eoeun-dong Yuseong-gu, Daejeon 305-333, South Korea

Cheonggil Jin

Korea Aerospace Research Institute, 45 Eoeun-dong Yuseong-gu, Daejeon 305-333, South Korea

Chuluong Choi

Pukyong National University, Department of Spatial Information Engineering, 45 Yongso-ro, Nam-gu, Busan 608-737, South Korea

Hyosuk Lim

Korea Aerospace Research Institute, 45 Eoeun-dong Yuseong-gu, Daejeon 305-333, South Korea

Yongseung Kim

Korea Aerospace Research Institute, 45 Eoeun-dong Yuseong-gu, Daejeon 305-333, South Korea

Jinsoo Kim

ZEN21, 2nd Floor, RNC Building, 981-1 Bangbae 3-dong, Seocho-gu, Seoul 137-848, South Korea

J. Appl. Remote Sens. 6(1), 063594 (Oct 30, 2012). doi:10.1117/1.JRS.6.063594
History: Received February 6, 2012; Revised August 29, 2012; Accepted September 17, 2012
Text Size: A A A

Abstract.  This paper presents absolute radiometric calibration coefficients (gains) that explain the relationship between the digital number (DN) and at-sensor radiance for the multispectral camera (MSC) on Korea’s first high-resolution satellite (KOMPSAT-2). Absolute radiometric calibration was performed using a reflectance-based method. In addition, the suitability of vicarious results from radiance- and reflectance-based validations was analyzed with reference to IKONOS and QuickBird images. The latter are spectrally similar to KOMPSAT-2 images and have been validated in a large number of studies. For all bands, the R2 values of fitted lines for the gain ranged from 0.82 to 0.94, representing an improvement compared to previous findings for the KOMPSAT-2 MSC. To analyze the suitability of the vicarious results, same-pixel at-sensor radiances across different spectral bands were compared. In all bands, except the red band of QuickBird, the at-sensor radiances of KOMPSAT-2 MSC were highly correlated with those of IKONOS and QuickBird. In addition, same-pixel comparisons of reflectance across different spectral bands showed that the slopes of the least-squares lines for each band were similar to the results of the radiance comparison. The standard deviation among top of atmosphere (TOA) reflectances was within 0.019 for all bands. To calculate the tasseled cap transformation (TCT) coefficients for the KOMPSAT-2 MSC, an empirical method was applied using radiometric normalization. The results were similar to those obtained using the TCT coefficients for IKONOS and QuickBird in the brightness, greenness, and wetness components. The TCT images showed similar patterns. The absolute radiometric calibration coefficients presented here appear to be a good standard for maintaining the optical quality of the KOMPSAT-2 MSC, for which prelaunch, on-board, and vicarious calibration data are lacking.

Figures in this Article
© 2012 Society of Photo-Optical Instrumentation Engineers

Citation

Sungu Lee ; Cheonggil Jin ; Chuluong Choi ; Hyosuk Lim ; Yongseung Kim, et al.
"Absolute radiometric calibration of the KOMPSAT-2 multispectral camera using a reflectance-based method and empirical comparison with IKONOS and QuickBird images", J. Appl. Remote Sens. 6(1), 063594 (Oct 30, 2012). ; http://dx.doi.org/10.1117/1.JRS.6.063594


Access This Article
Sign In to Access Full Content
Please Wait... Processing your request... Please Wait.
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).
 
Your Session has timed out. Please sign back in to continue.
Sign In to Access Full Content

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement


Buy this article ($18 for members, $25 for non-members).
Sign In