Presentation
13 March 2024 Assessment of the biomechanical impact of LASIK refractive surgery in human corneas using wave-based optical coherence elastography
Fernando Zvietcovich, Alejandra Varea, Judith Birkenfeld, Andrea Curatolo, Jesus Merayo-Lloves, Susana Marcos
Author Affiliations +
Abstract
The impact of LASIK surgery on corneal biomechanics remains unclear. To address this, we used air-coupled ultrasonic optical coherence elastography (ACUS-OCE) system to examine the full spatial-dependent elasticity of corneas before and after LASIK. We measured Lamb wave propagation speed and average corneal thickness in 16 semi-meridians to calculate the Shear Modulus (G) in 30 healthy control subjects (n=60 corneas) and 8 patients (n= 16 corneas) pre- and 1-month post-LASIK. G decreased from 52±4 kPa to 43±5 kPa after LASIK intervention. In summary, LASIK decreased corneal stiffness, which is consistent with the loss of anterior stroma containing high lamellae interweaving.
Conference Presentation
© (2024) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Fernando Zvietcovich, Alejandra Varea, Judith Birkenfeld, Andrea Curatolo, Jesus Merayo-Lloves, and Susana Marcos "Assessment of the biomechanical impact of LASIK refractive surgery in human corneas using wave-based optical coherence elastography", Proc. SPIE PC12844, Optical Elastography and Tissue Biomechanics XI, PC128440I (13 March 2024); https://doi.org/10.1117/12.3003433