Paper
5 May 1986 Aperture-dependent Electron Beam Lifetime For The BESSY Storage Ring
P. Kuske, A. Gaupp, W.-D. Klotz, R. Maier, G. Mulhaupt, W. B. Peatman, J. Pfluger, E. Weihreter, W. Gudat
Author Affiliations +
Proceedings Volume 0582, Insertion Devices for Synchrotron Sources; (1986) https://doi.org/10.1117/12.950923
Event: International Conference on Insertion Devices for Synchrotron Sources, 1985, Stanford, United States
Abstract
The dependence of electron beam lifetime on vertical aperture is measured for the storage ring BESSY providing quantitative information necessary for estimating the usable gap sizes of the variable vacuum gap undulator presently being built. The data allow one to distinguish between different lifetime limiting mechanisms thus yielding useful storage ring diagnostics. General agreement with available particle loss models is observed.
© (1986) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
P. Kuske, A. Gaupp, W.-D. Klotz, R. Maier, G. Mulhaupt, W. B. Peatman, J. Pfluger, E. Weihreter, and W. Gudat "Aperture-dependent Electron Beam Lifetime For The BESSY Storage Ring", Proc. SPIE 0582, Insertion Devices for Synchrotron Sources, (5 May 1986); https://doi.org/10.1117/12.950923