5 September 2017 Operational correction and validation of the VIIRS TEB longwave infrared band calibration bias during blackbody temperature changes
Wenhui Wang, Changyong Cao, Alex Ignatov, Zhenglong Li, Likun Wang, Bin Zhang, Slawomir Blonski, Jun Li
Author Affiliations +
Abstract
The Suomi NPP VIIRS thermal emissive bands (TEB) have been performing very well since data became available on January 20, 2012. The longwave infrared bands at 11 and 12 um (M15 and M16) are primarily used for sea surface temperature (SST) retrievals. A long standing anomaly has been observed during the quarterly warm-up-cool-down (WUCD) events. During such event daytime SST product becomes anomalous with a warm bias shown as a spike in the SST time series on the order of 0.2 K. A previous study (CAO et al. 2017) suggested that the VIIRS TEB calibration anomaly during WUCD is due to a flawed theoretical assumption in the calibration equation and proposed an Ltrace method to address the issue. This paper complements that study and presents operational implementation and validation of the Ltrace method for M15 and M16. The Ltrace method applies bias correction during WUCD only. It requires a simple code change and one-time calibration parameter look-up-table update. The method was evaluated using colocated CrIS observations and the SST algorithm. Our results indicate that the method can effectively reduce WUCD calibration anomaly in M15, with residual bias of ~0.02 K after the correction. It works less effectively for M16, with residual bias of ~0.04 K. The Ltrace method may over-correct WUCD calibration biases, especially for M16. However, the residual WUCD biases are small in both bands. Evaluation results using the SST algorithm show that the method can effectively remove SST anomaly during WUCD events.
© (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Wenhui Wang, Changyong Cao, Alex Ignatov, Zhenglong Li, Likun Wang, Bin Zhang, Slawomir Blonski, and Jun Li "Operational correction and validation of the VIIRS TEB longwave infrared band calibration bias during blackbody temperature changes", Proc. SPIE 10402, Earth Observing Systems XXII, 104021P (5 September 2017); https://doi.org/10.1117/12.2272377
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Black bodies

Sensors

Infrared radiation

Long wavelength infrared

Back to Top