The capability is described with an emphasis on the physical reflectance models used to predict spectral reflectivity signatures as a function of surface contaminant presentation and loading. Developmental test results from a breadboard version of the detector platform are presented. Specifically, solid and liquid surface contaminants were detected and identified from a library of 325 compounds down to 30 μg/cm2 surface loading at a 5 m standoff. Vapor detection was demonstrated via topographic backscatter. |
|