In this paper we describe ProtoGECCO–a prototype instrument for the Galactic Explorer with a Coded aperture mask and Compton Telescope (GECCO). ProtoGECCO is comprised of two main imaging calorimeters. The top calorimeter is an array of cadmium zinc telluride (CZT); the bottom calorimeter is an array of high-light yield Gd3Al2Ga3O12:Ce (GAGG) fingers with silicon photomultiplier (SiPM) readout. The calorimeters are surrounded by a thallium-doped cesium iodide (CsI:Tl) active shield. ProtoGECCO employs the techniques of both coded aperture imaging and a Compton telescope. The main goals of the prototype are to further develop the instrument technology, thereby raising the technical readiness level (TRL), and to fly on a high-altitude balloon from Fort Sumner, NM. The results of this work are directly applicable to future space instruments that require detectors with large area; excellent spatial, energy, and angular resolution; and high detection efficiency. Such future missions will address problems in the MeV domain of gamma-ray astronomy—one of the most underexplored windows on the universe.
|