Presentation + Paper
4 October 2023 Prelaunch radiometric calibration of the thermal response of the PACE Ocean Color Instrument
Author Affiliations +
Abstract
The NASA Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission Ocean Color Instrument Team has completed the prelaunch radiometric characterization of the thermal response of the Ocean Color Instrument (OCI). The radiometric performance of the ultraviolet to visible (UVVIS) and visible to near-infrared (VISNIR) grating spectrographs and the shortwave-infrared (SWIR) filter spectrograph of OCI were characterized during the thermal vacuum testing of the instrument conducted in September and October of 2022. The thermal characterization test program will be outlined, along with the derived radiometric dependencies on temperature. For the UVVIS and VISNIR spectrographs, the change in radiometric response with temperature is consistent with theoretical models of the measured detector performance and is on the order of 0.15% per °C. For the SWIR spectrograph, the change in radiometric response with temperature in on the order of 0.04% per °C. For the UVVIS spectrograph, uncertainties in the radiometric measurements as the detector temperatures varied by ∼10° C were less than 0.15% for wavelengths of 350 − 593 nm. For the VISNIR spectrograph, uncertainties were less than 0.11% for wavelengths of 625 − 867 nm. For the SWIR spectrograph, the typical uncertainties were less than 0.15% for all bands. Since the expected temperature range for the instrument on orbit is 0.5° C, OCI meets the design goals for upper limits on radiometric uncertainties due to thermal effects.
Conference Presentation
(2023) Published by SPIE. Downloading of the abstract is permitted for personal use only.
Robert E. Eplee Jr., Gerhard Meister, Shihyan Lee, Kenneth J. Squire, Ulrik Gliese, Joseph J. Knuble, and Deepak Patel "Prelaunch radiometric calibration of the thermal response of the PACE Ocean Color Instrument", Proc. SPIE 12685, Earth Observing Systems XXVIII, 1268509 (4 October 2023); https://doi.org/10.1117/12.2677463
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Equipment

Short wave infrared radiation

Temperature metrology

Spectral response

Calibration

Spectrographs

Charge-coupled devices

RELATED CONTENT

Onboard calibration status of ASTER
Proceedings of SPIE (October 03 2006)
ASTER on-board calibration status
Proceedings of SPIE (October 09 2008)
ASTER on-board calibration status
Proceedings of SPIE (April 08 2003)

Back to Top