Paper
1 October 1990 Infrared response of YBa2Cu3O7-delta films to pulsed broadband synchrotron radiation
G. Lawrence Carr, Manuel A. Quijada, David B. Tanner, Carol J. Hirschmugl, Gwyn P. Williams, Shahab Etemad, F. De Rosa, T. Venkatesan, Barundeb Dutta, D. Hemmick, Xiaoxing Xi
Author Affiliations +
Abstract
We report studies of a thin high-Ta film operating as a fast bolometric detector of infrared radiation. The film has a response of several mV when exposed to a 1 W, 1 ns duration broadband infrared pulse. The decay after the pulse was about 4 ns. The temperature dependence of the response accurately tracked dR/dT. A thermal model, in which the film's temperature varies relative to the substrate, provides a good description of the response. We find no evidence for other (non-bolometric) response mechanisms for temperatures near or well below T.
© (1990) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
G. Lawrence Carr, Manuel A. Quijada, David B. Tanner, Carol J. Hirschmugl, Gwyn P. Williams, Shahab Etemad, F. De Rosa, T. Venkatesan, Barundeb Dutta, D. Hemmick, and Xiaoxing Xi "Infrared response of YBa2Cu3O7-delta films to pulsed broadband synchrotron radiation", Proc. SPIE 1292, Superconductivity Applications for Infrared and Microwave Devices, (1 October 1990); https://doi.org/10.1117/12.21044
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Infrared radiation

Bridges

Synchrotron radiation

Sensors

Bolometers

Resistance

Far infrared

Back to Top