1 February 1994 Calibration of Astro-D telescope with an x-ray pencil beam
Yoshiyuki Tsusaka, Hisanori Suzuki, Hisamitsu Awaki, Koujun Yamashita, Hideyo Kunieda, Yuzuru Tawara, Yasushi Ogasaka, Yasuhiro Uchibori, Hirohiko Honda, Masayuki Itoh, Hiroshi Tsunemi, Kiyoshi Hayashida, Susumu Nomoto, Mikio Wada, Emi Miyata, Peter J. Serlemitsos, Lalit Jalota, Yang Soong
Author Affiliations +
Abstract
The x-ray optical properties of X-Ray Telescopes (XRTs) on board Asca were evaluated with an x-ray pencil beam at ISAS 30 m x-ray beam line. The total effective area of four XRTs is obtained to be about 1300 cm2, 800 cm2, and 450 cm2 at each energy of 1.5 keV, 4.5 keV, and 8.0 keV, respectively. These values are about 15% less than those calculated by ray tracing method in an ideal case. The shadow effect of closely packed foils might be the main reason for the degradation of effective area. The Point Spread Function of XRT was also measured by an x-ray CCD. We have also measured the contamination of stray light, which were caused by the one time reflected photons (by primary or secondary mirror) and photons reflected on the back side surface of the mirror shells. The stray light profile and intensity were consistent to the results simulated by the ray tracing.
© (1994) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yoshiyuki Tsusaka, Hisanori Suzuki, Hisamitsu Awaki, Koujun Yamashita, Hideyo Kunieda, Yuzuru Tawara, Yasushi Ogasaka, Yasuhiro Uchibori, Hirohiko Honda, Masayuki Itoh, Hiroshi Tsunemi, Kiyoshi Hayashida, Susumu Nomoto, Mikio Wada, Emi Miyata, Peter J. Serlemitsos, Lalit Jalota, and Yang Soong "Calibration of Astro-D telescope with an x-ray pencil beam", Proc. SPIE 2011, Multilayer and Grazing Incidence X-Ray/EUV Optics II, (1 February 1994); https://doi.org/10.1117/12.167219
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

X-ray telescopes

Mirrors

Ray tracing

Charge-coupled devices

Space telescopes

Calibration

RELATED CONTENT

Reducing the optical and x ray stray light In the...
Proceedings of SPIE (April 03 2018)
Use of x ray CCDs in the calibration of the...
Proceedings of SPIE (October 31 1996)
GOES N P SXI in flight calibration using the Crab...
Proceedings of SPIE (August 29 2006)
X ray calibration of the GOES N O solar X...
Proceedings of SPIE (February 04 2004)
The Swift X-Ray Telescope
Proceedings of SPIE (February 03 2004)
Simbol-X: x-ray baffle for stray-light reduction
Proceedings of SPIE (September 20 2007)

Back to Top