Paper
1 April 1994 Influence of display and observer responses in receiver operating characteristic (ROC) experiments
Author Affiliations +
Abstract
Medical image quality can be defined in terms of observer performances in detecting image abnormalities, since diagnosis is essentially based on visual inspection of medical images. There exists a large body of theoretical and experimental work specifying it in terms of signal to noise ratio, area under the ROC curve, and detectability index. However, the comparison between the theoretical and experimental figures of merit (FOMs) is made difficult because FOMs do operate on different signals and observers. In this paper we investigate the relationships between such signals, observers, and FOMs; the soundness of the underlying assumptions; and the possibility of optimizing image display. In section 2 we define three signal-observer pairs for which the main theoretical and experimental results are recalled. We also present the results obtained in our lab to show their consistency with results found in the literature. In section 3 we describe an experiment designed to evaluate the relationships between the three types of signal-observer pairs, and to assess the robustness of the model with respect to the assumptions. We also present in this section the results of this experiment. In section 4 these results and the relevance of FOMs are discussed.
© (1994) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
C. Orieux, Jeanpierre V. Guedon, and Yves J. Bizais "Influence of display and observer responses in receiver operating characteristic (ROC) experiments", Proc. SPIE 2166, Medical Imaging 1994: Image Perception, (1 April 1994); https://doi.org/10.1117/12.171742
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Signal to noise ratio

Digital imaging

Target detection

Sensors

Medical imaging

Interference (communication)

Image processing

RELATED CONTENT

Novel model based EMI processing framework
Proceedings of SPIE (May 03 2017)
Minimum resolvable power contrast model
Proceedings of SPIE (January 12 2018)
Human Signal Detection Performance For Noisy Medical Images
Proceedings of SPIE (November 01 1982)
Particle-based track-before-detect in Rayleigh noise
Proceedings of SPIE (August 25 2004)
Detection and tracking of a moving point target in a...
Proceedings of SPIE (October 22 1993)
Signal-to-Noise Frequency Analysis of CT Systems
Proceedings of SPIE (May 01 1989)

Back to Top