13 September 1996 Scalability of conventional and sidewall-sealed LOCOS technology for 256-Mbit DRAM array and periphery isolation
Mark Rodder, Jeong-Mo Hwang, Ih-Chin Chen
Author Affiliations +
Abstract
LOCOS technology is being investigated for applicability to 256 Mbit DRAM applications in the memory array (with active region pitch < 0.6 micrometers ) as well as the periphery. In this paper, LOCOS isolation is demonstrated for array n--n- spacing < 0.2 micrometers for 256 Mbit DRAM array and for n+-n+ (and p+-p+) spacing < 0.35 micrometers for DRAM periphery. Array nMOSFETs with small active width of 0.2 micrometers are demonstrated with Ioff < lfA/micrometers (VB equals IV) at Lo equals 0.2 micrometers while maintaining low VT (<VTspec equals 1.5 V at VB equals 4 V) at Lo equals 0.3 micrometers in accordance with DRAM pass transistor design. These key results are obtained with appropriate LDD dose and energy, sidewall sealed LOCOS isolation, and 1100 degree(s)C field oxidation to reduce both field oxide thinning and active width encroachment. MOSFETs with sidewall sealed LOCOS show small narrow width effect, (Delta) VT/(Delta) W, and no sub-VT `double-hump'. In contrast, conventional LOCOS results in high (Delta) VT/(Delta) W for MOSFETs with active width < 0.4 micrometers while recessed LOCOS causes sub- VT `double-hump' for large active width MOSFETs.
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Mark Rodder, Jeong-Mo Hwang, and Ih-Chin Chen "Scalability of conventional and sidewall-sealed LOCOS technology for 256-Mbit DRAM array and periphery isolation", Proc. SPIE 2875, Microelectronic Device and Multilevel Interconnection Technology II, (13 September 1996); https://doi.org/10.1117/12.250870
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Oxides

Oxidation

Transistors

Field effect transistors

Diodes

Silicon

Dielectrics