Paper
1 April 1998 Absolute calibration of charge-coupled devices to hard 8- to 98-keV x rays
James Dunn, Alan D. Conder, Richard E. Stewart
Author Affiliations +
Proceedings Volume 3301, Solid State Sensor Arrays: Development and Applications II; (1998) https://doi.org/10.1117/12.304551
Event: Photonics West '98 Electronic Imaging, 1998, San Jose, CA, United States
Abstract
We describe experimental techniques for characterizing the absolute response of charge-coupled devices (CCD) to incident hard x-rays using the high energy x-ray source at the Lawrence Livermore National Laboratory. We present responsivity and quantum detection efficiency measurements for a standard, front-illuminated, scientific CCD to monoenergetic 8-98 keV K-(alpha) x-rays. This systematic study out to high energies reveals the contribution of different absorption processes to the CCD detection efficiency. For lower energies below 20 keV the CCD behaves like an ideal photoelectric detector as expected. Increasingly above 40 keV the photoelectric effect in the CCD epitaxial region is augmented by incoherent or Compton scattering where a fraction of the energy from the photon scattering event is transferred to the electrons and subsequently detected. The Compton scattering mechanism dominates the photoelectric effect above 100 keV giving the CCD a predicted detection efficiency which remains constant from 150 keV to 1 MeV assuming that the scattered electrons finally come to rest within the active region. These physics issues will be briefly discussed and are particularly relevant to deep active region solid-state detectors with application for hard x-ray detection above 40 keV.
© (1998) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
James Dunn, Alan D. Conder, and Richard E. Stewart "Absolute calibration of charge-coupled devices to hard 8- to 98-keV x rays", Proc. SPIE 3301, Solid State Sensor Arrays: Development and Applications II, (1 April 1998); https://doi.org/10.1117/12.304551
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Charge-coupled devices

X-rays

Absorption

Sensors

Calibration

Scattering

Quantum efficiency

RELATED CONTENT

Using tritium and x ray tubes as x ray calibration...
Proceedings of SPIE (October 31 1996)
Progress in x ray CCD sensor performance for the Astro...
Proceedings of SPIE (September 29 2004)
Multilayer x-ray-sensitive CCDs
Proceedings of SPIE (April 30 2002)
Frame store PN-CCD detector for space applications
Proceedings of SPIE (February 03 2004)
Near edge structure in the soft x ray quantum efficiency...
Proceedings of SPIE (September 16 1994)

Back to Top