Paper
22 June 1999 Condenser-discharge stroboscopic x-ray generator SX-C98
Eiichi Sato, Toshio Ichimaru, Tatsumi Usuki, Koetsu Sato, Hidenori Ojima, Kazuyoshi Takayama, Hideaki Ido, Kimio Sakamaki, Yoshiharu Tamakawa
Author Affiliations +
Proceedings Volume 3516, 23rd International Congress on High-Speed Photography and Photonics; (1999) https://doi.org/10.1117/12.350542
Event: Twenty-Third International Congress on High-Speed Photography and Photonics, 1998, Moscow, Russian Federation
Abstract
The radiographic characteristics of a high-intensity kilohertz-range stroboscopic x-ray generator (SX-C98) are described. This generator consists of the following major components: a controller, a condenser unit having a Cockcroft circuit, and an x-ray tube unit in conjunction with a grid controller. The main condenser of about 500 nF in the unit is charged up to 100 kV by the circuit, and the electric charges in the condenser are discharged to the triode by the grid controller. Although the tube voltage slightly decreased during the discharging for generating x-rays, the maximum value was equivalent to the initial charging voltage of the main condenser. The maximum values of the tube current and the repetition rate were about 0.5 A and 32 kHz, respectively. The pulse width of the x-rays ranged from approximately 0.01 to 1.0 ms, and the maximum shot number had a value of 32. At a constant filament (cathode) temperature, the x-ray intensity increased according to increases in the charging voltage and to increases in the duration, and the intensity with a duration of about Ims and a charging voltage of 70 kV was 140 nC/kg at 1.0 m per pulse. When the charging voltage was increased, the dimension of the focal spot slightly increased, and the maximum values were about 3.5 X 3.5 mm.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Eiichi Sato, Toshio Ichimaru, Tatsumi Usuki, Koetsu Sato, Hidenori Ojima, Kazuyoshi Takayama, Hideaki Ido, Kimio Sakamaki, and Yoshiharu Tamakawa "Condenser-discharge stroboscopic x-ray generator SX-C98", Proc. SPIE 3516, 23rd International Congress on High-Speed Photography and Photonics, (22 June 1999); https://doi.org/10.1117/12.350542
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

X-ray imaging

Electrodes

Virtual colonoscopy

Metals

Photomultipliers

Picosecond phenomena

Back to Top