Paper
27 April 2000 Laboratory simulation of high-frequency GPR responses of damaged tunnel liners
A. F. Siggins, Robert J. Whiteley
Author Affiliations +
Proceedings Volume 4084, Eighth International Conference on Ground Penetrating Radar; (2000) https://doi.org/10.1117/12.383519
Event: 8th International Conference on Ground Penetrating Radar, 2000, Gold Coast, Australia
Abstract
Concrete lined tunnels and pipelines commonly suffer from damage due to subsidence or poor drainage in the surrounding soils, corrosion of reinforcement if present, and acid vapor leaching of the lining. There is a need to conduct tunnel condition monitoring using non-destructive testing methods (NDT) on a regular basis in many buried installations, for example sewers and storm water drains. A wide variety of NDT methods have been employed in the past to monitor these linings including closed circuit TV (CCTV) inspection, magnetic and various electromagnetic and seismic methods. Ground penetrating radar, GPR, is a promising technique for this application, however there are few systems currently available that can provide the high resolution imaging needed to test the lining. A recently developed Australian GPR system operating at 1400 MHz offers the potential to overcome many of these limitations while maintaining adequate resolution to the rear of the linings which are typically less than 0.5 meters thick. The new high frequency GPR has a nominal resolution of 0.03 m at the center of the pulse band-width. This is a significant improvement over existing radars with the possible exception of some horn based systems. This paper describes the results of a laboratory study on a model tunnel lining using the new 1.4 GHz radar. The model simulated a concrete lining with various degrees of damage including, heavily leached sections, voids and corroded reinforcing. The test results established that the new GPR was capable of imaging subtle variations in the concrete structure and that simulated damage could be detected throughout the liner depth. Furthermore, resolution was found to exceed 0.02 m which was significantly better than expected.
© (2000) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
A. F. Siggins and Robert J. Whiteley "Laboratory simulation of high-frequency GPR responses of damaged tunnel liners", Proc. SPIE 4084, Eighth International Conference on Ground Penetrating Radar, (27 April 2000); https://doi.org/10.1117/12.383519
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.