Paper
29 June 2001 Infrared radiometer with digital signal processing for medical applications
G. G. Porumb, Andreea-Rodica P. Sterian, Oana Spulber, Mihai C. Piscureanu
Author Affiliations +
Proceedings Volume 4430, ROMOPTO 2000: Sixth Conference on Optics; (2001) https://doi.org/10.1117/12.432907
Event: ROMOPTO 2000: Sixth Conference on Optics, 2000, Bucharest, Romania
Abstract
In this paper we present our results concerning the study, design and construction of an infrared radiometer with digital signal processing for medical applications. The design and the practical realization of the system included an a priori study for performing the parameters analysis, both for the radiation source and the detector range, and it can be used for measuring with the desired resolution of the signal power in relation with the diagnosed situations. The pyroelectric type sensor represents the reference element of the system, so that in function of its type and parameters we have designed the source pointing optical ensemble as well as the electronics required for the detector output signal processing. The interface with the operator gives us the possibility of controlling the accuracy of the measurements by using a computer terminal, and also to monitorize the measured values and to modify the parameters by means of an external signal.
© (2001) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
G. G. Porumb, Andreea-Rodica P. Sterian, Oana Spulber, and Mihai C. Piscureanu "Infrared radiometer with digital signal processing for medical applications", Proc. SPIE 4430, ROMOPTO 2000: Sixth Conference on Optics, (29 June 2001); https://doi.org/10.1117/12.432907
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication and 3 patents.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Signal processing

Digital signal processing

Radiometry

Infrared radiation

Signal detection

Microcontrollers

RELATED CONTENT

Parsimonious Sampling For Scanning Mosaic Sensors
Proceedings of SPIE (September 20 1987)
CATAVIÑA: new infrared camera for OAN-SPM
Proceedings of SPIE (June 15 2006)
An Optical Infrared Staring Radiometer
Proceedings of SPIE (October 03 1988)
New technologies for staring infrared FPA radiometry
Proceedings of SPIE (August 13 1997)
Multi-Detector Thermal Imagers
Proceedings of SPIE (January 21 1985)

Back to Top