11 May 2004 Preliminary yield measurements in the ElectriCOIL system
David L. Carroll, Joseph T. Verdeyen, Darren M. King, G. Benavides, B. S. Woodard, N. Richardson, Wayne C. Solomon, W. Terry Rawlins, Steven J. Davis, William J. Kessler
Author Affiliations +
Abstract
Preliminary measurements of the yield of O2(1Δ) as a function of power absorbed in an RF discharge are presented. The yield is deduced from measurements of gain/absorption using the PSI Iodine Scan diagnostic coupled with a data reduction technique originally developed by PSI. A more formal presentation of the method of deducing the yield is provided. Atomic oxygen titration experiments are presented along with gain as a function of power input to the system.
© (2004) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
David L. Carroll, Joseph T. Verdeyen, Darren M. King, G. Benavides, B. S. Woodard, N. Richardson, Wayne C. Solomon, W. Terry Rawlins, Steven J. Davis, and William J. Kessler "Preliminary yield measurements in the ElectriCOIL system", Proc. SPIE 5334, Gas and Chemical Lasers, and Applications III, (11 May 2004); https://doi.org/10.1117/12.537749