Paper
5 January 2006 Reliability testing and qualification of the TeraVicta RF MEMS switch
Author Affiliations +
Abstract
This paper presents the results of work by Teravicta Technologies to adapt semiconductor industry standards and practices to the qualification of RF MEMS switch components. This includes an overview of parametric test data including contact resistance and key RF performance indicators (insertion loss, return loss, and isolation) and reliability test results, identification of key failure modes, the development of failure accelerants and accelerated life test procedures, and final qualification results. Although some tests are unique to the RF MEMS switch, the methodology presented here provides a sound starting point for the development of qualification procedures for other MEMS devices.
© (2006) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
John S. McKillop "Reliability testing and qualification of the TeraVicta RF MEMS switch", Proc. SPIE 6111, Reliability, Packaging, Testing, and Characterization of MEMS/MOEMS V, 61110B (5 January 2006); https://doi.org/10.1117/12.648776
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Switches

Microelectromechanical systems

Reliability

Resistance

Metals

Accelerated life testing

Manufacturing

Back to Top