Paper
22 March 2007 Target error for image-to-physical space registration: preliminary clinical results using laser range scanning
Aize Cao, Michael I. Miga, P. Dumpuri, S. Ding, B. M. Dawant, R. C. Thompson M.D.
Author Affiliations +
Abstract
In this paper, preliminary results from an image-to-physical space registration platform are presented. The current platform employs traditional and novel methods of registration which use a variety of data sources to include: traditional synthetic skin-fiducial point-based registration, surface registration based on facial contours, brain feature point-based registration, brain vessel-to-vessel registration, and a more comprehensive cortical surface registration method that utilizes both geometric and intensity information from both the image volume and physical patient. The intraoperative face and cortical surfaces were digitized using a laser range scanner (LRS) capable of producing highly resolved textured point clouds. In two in vivo cases, a series of registrations were performed using these techniques and compared within the context of a true target error. One of the advantages of using a textured point cloud data stream is that true targets among the physical cortical surface and the preoperative image volume can be identified and used to assess image-to-physical registration methods. The results suggest that iterative closest point (ICP) method for intraoperative face surface registration is equivalent to point-based registration (PBR) method of skin fiducial markers. With regard to the initial image and physical space registration, for patient 1, mean target registration error (TRE) were 3.1±0.4 mm and 3.6 ±0.9 mm for face ICP and skin fiducial PBR, respectively. For patient 2, the mean TRE were 5.7 ±1.3 mm, and 6.6 ±0.9 mm for face ICP and skin fiducial PBR, respectively. With regard to intraoperative cortical surface registration, SurfaceMI outperformed feature based PBR and vessel ICP with 1.7±1.8 mm for patient 1. For patient 2, the best result was achieved by using vessel ICP with 1.9±0.5 mm.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Aize Cao, Michael I. Miga, P. Dumpuri, S. Ding, B. M. Dawant, and R. C. Thompson M.D. "Target error for image-to-physical space registration: preliminary clinical results using laser range scanning", Proc. SPIE 6509, Medical Imaging 2007: Visualization and Image-Guided Procedures, 65091D (22 March 2007); https://doi.org/10.1117/12.711496
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image registration

Lawrencium

Skin

Brain

Clouds

Magnetic resonance imaging

Calibration

Back to Top