Paper
10 March 2009 Breast density measurement: 3D cone beam computed tomography (CBCT) images versus 2D digital mammograms
Author Affiliations +
Proceedings Volume 7258, Medical Imaging 2009: Physics of Medical Imaging; 72580L (2009) https://doi.org/10.1117/12.813823
Event: SPIE Medical Imaging, 2009, Lake Buena Vista (Orlando Area), Florida, United States
Abstract
Breast density has been recognized as one of the major risk factors for breast cancer. However, breast density is currently estimated using mammograms which are intrinsically 2D in nature and cannot accurately represent the real breast anatomy. In this study, a novel technique for measuring breast density based on the segmentation of 3D cone beam CT (CBCT) images was developed and the results were compared to those obtained from 2D digital mammograms. 16 mastectomy breast specimens were imaged with a bench top flat-panel based CBCT system. The reconstructed 3D CT images were corrected for the cupping artifacts and then filtered to reduce the noise level, followed by using threshold-based segmentation to separate the dense tissue from the adipose tissue. For each breast specimen, volumes of the dense tissue structures and the entire breast were computed and used to calculate the volumetric breast density. BI-RADS categories were derived from the measured breast densities and compared with those estimated from conventional digital mammograms. The results show that in 10 of 16 cases the BI-RADS categories derived from the CBCT images were lower than those derived from the mammograms by one category. Thus, breasts considered as dense in mammographic examinations may not be considered as dense with the CBCT images. This result indicates that the relation between breast cancer risk and true (volumetric) breast density needs to be further investigated.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Tao Han, Chao-Jen Lai, Lingyun Chen, Xinming Liu, Youtao Shen, Yuncheng Zhong, Shuaiping Ge, Ying Yi, Tianpeng Wang, Wei T Yang, and Chris C. Shaw "Breast density measurement: 3D cone beam computed tomography (CBCT) images versus 2D digital mammograms", Proc. SPIE 7258, Medical Imaging 2009: Physics of Medical Imaging, 72580L (10 March 2009); https://doi.org/10.1117/12.813823
Lens.org Logo
CITATIONS
Cited by 10 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Breast

Image segmentation

Tissues

Mammography

3D image processing

Computed tomography

Breast cancer

Back to Top