Paper
12 March 2009 Non-localization and localization ROC analyses using clinically based scoring
Author Affiliations +
Abstract
We are investigating the potential for differences in study conclusions when assessing the estimated impact of a computer-aided detection (CAD) system on readers' performance. The data utilized in this investigation were derived from a multi-reader multi-case observer study involving one hundred mammographic background images to which fixed-size and fixed-intensity Gaussian signals were added, generating a low- and high-intensity signal sets. The study setting allowed CAD assessment in two situations: when CAD sensitivity was 1) superior or 2) lower than the average reader. Seven readers were asked to review each set in the unaided and CAD-aided reading modes, mark and rate their findings. Using this data, we studied the effect on study conclusion of three clinically-based receiver operating characteristic (ROC) scoring definitions. These scoring definitions included both location-specific and non-location-specific rules. The results showed agreement in the estimated impact of CAD on the overall reader performance. In the study setting where CAD sensitivity is superior to the average reader, the mean difference in AUC between the CAD-aided read and unaided read was 0.049 (95%CIs: -0.027; 0.130) for the image scoring definition that is based on non-location-specific rules, and 0.104 (95%CIs: 0.036; 0.174) and 0.090 (95%CIs: 0.031; 0.155) for image scoring definitions that are based on location-specific rules. The increases in AUC were statistically significant for the location-specific scoring definitions. It was further observed that the variance on these estimates was reduced when using the location-specific scoring definitions compared to that using a non-location-specific scoring definition. In the study setting where CAD sensitivity is equivalent or lower than the average reader, the mean differences in AUC are slightly above 0.01 for all image scoring definitions. These increases in AUC were not statistical significant for any of the image scoring definitions. The results on the variance analysis differed from those observed in the other study setting. This investigation furthers our understanding of the relationships between non-localization-specific and localization-specific ROC assessment methodologies and their relevance to clinical practice.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Sophie Paquerault, Frank W. Samuelson, Kyle J. Myers, and Robert C. Smith "Non-localization and localization ROC analyses using clinically based scoring", Proc. SPIE 7263, Medical Imaging 2009: Image Perception, Observer Performance, and Technology Assessment, 72630U (12 March 2009); https://doi.org/10.1117/12.813761
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Computer aided design

Selenium

Computer aided diagnosis and therapy

Receivers

Statistical analysis

Computing systems

Signal detection

Back to Top