Paper
30 October 2009 Detection of whole-brain abnormalities in temporal lobe epilepsy using tensor-based morphometry with DARTEL
Wenjing Li, Huiguang He, Jingjing Lu, Bin Lv, Meng Li, Zhengyu Jin
Author Affiliations +
Proceedings Volume 7497, MIPPR 2009: Medical Imaging, Parallel Processing of Images, and Optimization Techniques; 749723 (2009) https://doi.org/10.1117/12.833128
Event: Sixth International Symposium on Multispectral Image Processing and Pattern Recognition, 2009, Yichang, China
Abstract
Tensor-based morphometry (TBM) is an automated technique for detecting the anatomical differences between populations by examining the gradients of the deformation fields used to nonlinearly warp MR images. The purpose of this study was to investigate the whole-brain volume changes between the patients with unilateral temporal lobe epilepsy (TLE) and the controls using TBM with DARTEL, which could achieve more accurate inter-subject registration of brain images. T1-weighted images were acquired from 21 left-TLE patients, 21 right-TLE patients and 21 healthy controls, which were matched in age and gender. The determinants of the gradient of deformation fields at voxel level were obtained to quantify the expansion or contraction for individual images relative to the template, and then logarithmical transformation was applied on it. A whole brain analysis was performed using general lineal model (GLM), and the multiple comparison was corrected by false discovery rate (FDR) with p<0.05. For left-TLE patients, significant volume reductions were found in hippocampus, cingulate gyrus, precentral gyrus, right temporal lobe and cerebellum. These results potentially support the utility of TBM with DARTEL to study the structural changes between groups.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Wenjing Li, Huiguang He, Jingjing Lu, Bin Lv, Meng Li, and Zhengyu Jin "Detection of whole-brain abnormalities in temporal lobe epilepsy using tensor-based morphometry with DARTEL", Proc. SPIE 7497, MIPPR 2009: Medical Imaging, Parallel Processing of Images, and Optimization Techniques, 749723 (30 October 2009); https://doi.org/10.1117/12.833128
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Magnetic resonance imaging

Control systems

Brain

Epilepsy

Image registration

Neuroimaging

Image segmentation

Back to Top