Paper
18 March 2010 Design, optimization and testing of a multi-beam micro-CT scanner based on multi-beam field emission x-ray technology
R. Peng, J. Zhang, X. Calderon-Colon, S. Wang, S. Sultana, P. Wang, G. Yang, S. Chang, J. Lu, O. Zhou
Author Affiliations +
Abstract
As a widely adopted imaging modality for pre-clinical research, micro-CT is constantly facing the need of providing better temporal as well as spatial resolution for a variety of imaging applications. Faster CT scanning speed is also preferred for higher imaging throughput. We recently proposed a gantry-free multi-beam micro-CT (MBμCT) design which has the potential to overcome some of the intrinsic limitations of current rotating-gantry CT technology. To demonstrate its feasibility, we have constructed a testing system with a multi-beam field emission x-ray (MBFEX) source array with a linear array of 20 individually controllable x-ray emitting pixels. Based on simulations of the electron optics and preliminary experimental measurements the design of the MBFEX source has been further optimized. The newly designed imaging system has been characterized and commissioned following our standard imaging protocol. It has clearly shown improved system stability and enhanced imaging capability. As a result of reduced mechanical rotation during imaging acquisition, we are expecting to achieve higher CT scanning speed without significantly sacrificing imaging quality. This prototype MBμCT system, although still in its early development phase, has been proved to be an ideal testing platform for the proposed gantry-free micro-CT scanner.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
R. Peng, J. Zhang, X. Calderon-Colon, S. Wang, S. Sultana, P. Wang, G. Yang, S. Chang, J. Lu, and O. Zhou "Design, optimization and testing of a multi-beam micro-CT scanner based on multi-beam field emission x-ray technology", Proc. SPIE 7622, Medical Imaging 2010: Physics of Medical Imaging, 76221G (18 March 2010); https://doi.org/10.1117/12.843806
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Imaging systems

Scanners

Electrodes

X-ray sources

Sensors

X-ray detectors

RELATED CONTENT


Back to Top