22 March 2010 Daily quality control for breast tomosynthesis
R. W. Bouwman, R. Visser, K. C. Young, D. R. Dance, B. Lazzari, R. van der Burght, P. Heid, R. E. van Engen
Author Affiliations +
Abstract
Breast tomosynthesis is an imaging modality that recently became available for breast examination. For conventional projection mammography quality control procedures are well described. For breast tomosynthesis, on the other hand, such procedures have not yet been established. In this paper we propose a simple method and phantom for daily quality control (DQC). With DQC image quality problems arising after acceptance of the system should be detected. Therefore, the DQC procedure needs to monitor the stability of the most critical components of the system over time. For breast tomosynthesis we assume that the most critical items are the image receptor, X-ray tube and the tomosynthesis motion. In the proposed procedure the image receptor homogeneity and system stability are evaluated using an image of a homogeneous block of PMMA. The z-resolution is assumed to be dependent on the tomosynthesis motion. To monitor this motion the nominal z-resolution using the slice sensitive profile is measured. Shading artefacts that arise due to objects with high attenuation are also typical for tomosynthesis systems. Analysing those artefacts may provide additional information about the tomosynthesis motion. The proposed DQC procedure has been evaluated on two different breast tomosynthesis systems: A multi slit scanning system and a system using a stationary a-Se detector. Preliminary results indicate that the proposed method is useful for DQC, although some minor changes to the phantoms are advised. To verify that this method detects image quality problems sufficiently, more experience with different DBT systems, over longer periods of time are needed.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
R. W. Bouwman, R. Visser, K. C. Young, D. R. Dance, B. Lazzari, R. van der Burght, P. Heid, and R. E. van Engen "Daily quality control for breast tomosynthesis", Proc. SPIE 7622, Medical Imaging 2010: Physics of Medical Imaging, 762241 (22 March 2010); https://doi.org/10.1117/12.843759
Lens.org Logo
CITATIONS
Cited by 8 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Optical spheres

Breast

Signal to noise ratio

Reconstruction algorithms

Aluminum

Image quality

Image compression

Back to Top