Paper
2 March 2011 Modeling error in assessment of mammographic image features for improved computer-aided mammography training: initial experience
Author Affiliations +
Abstract
In this study we investigate the hypothesis that there exist patterns in erroneous assessment of BI-RADS image features among radiology trainees when performing diagnostic interpretation of mammograms. We also investigate whether these error making patterns can be captured by individual user models. To test our hypothesis we propose a user modeling algorithm that uses the previous readings of a trainee to identify whether certain BI-RADS feature values (e.g. "spiculated" value for "margin" feature) are associated with higher than usual likelihood that the feature will be assessed incorrectly. In our experiments we used readings of 3 radiology residents and 7 breast imaging experts for 33 breast masses for the following BI-RADS features: parenchyma density, mass margin, mass shape and mass density. The expert readings were considered as the gold standard. Rule-based individual user models were developed and tested using the leave one-one-out crossvalidation scheme. Our experimental evaluation showed that the individual user models are accurate in identifying cases for which errors are more likely to be made. The user models captured regularities in error making for all 3 residents. This finding supports our hypothesis about existence of individual error making patterns in assessment of mammographic image features using the BI-RADS lexicon. Explicit user models identifying the weaknesses of each resident could be of great use when developing and adapting a personalized training plan to meet the resident's individual needs. Such approach fits well with the framework of adaptive computer-aided educational systems in mammography we have proposed before.
© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Maciej A. Mazurowski and Georgia D. Tourassi "Modeling error in assessment of mammographic image features for improved computer-aided mammography training: initial experience", Proc. SPIE 7966, Medical Imaging 2011: Image Perception, Observer Performance, and Technology Assessment, 796607 (2 March 2011); https://doi.org/10.1117/12.878737
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Mammography

Solid modeling

Radiology

Computing systems

Systems modeling

Error analysis

Breast imaging

Back to Top