20 May 2011 Calibration methods and performance evaluation for pnCCDs in experiments with FEL radiation
N. Kimmel, R. Andritschke, L. Englert, S. Epp, A. Hartmann, R. Hartmann, G. Hauser, P. Holl, I. Ordavo, R. Richter, L. Strüder, J. Ullrich
Author Affiliations +
Abstract
Measurement campaigns of the Max-Planck Advanced Study Group (ASG) in cooperation with the Center for Free Electron Laser Science (CFEL) at DESY-FLASH and SLAC-LCLS have established pnCCDs as universal photon imaging spectrometers in the energy range from 90 eV to 2 keV. In the CFEL-ASG multi purpose chamber (CAMP), pnCCD detector modules are an integral part of the design with the ability to detect photons at very small scattering angles. In order to fully exploit the spectroscopic and intensity imaging capability of pnCCDs, it is essentially important to translate the unprocessed raw data into units of photon counts for any given position on the detection area. We have studied the performance of pnCCDs in FEL experiments and laboratory test setups for the range of signal intensities from a few X-ray photons per signal frame to 100 or more photons with an energy of 2 keV per pixel. Based on these measurement results, we were able to characterize the response of pnCCDs over the experimentally relevant photon energy and intensity range. The obtained calibration results are directly relevant for the physics data analysis. The accumulated knowledge of the detector performance was implemented in guidelines for detector calibration methods which are suitable for the specific requirements in photon science experiments at Free Electron Lasers. We discuss the achievable accuracy of photon energy and photon count measurements before and after the application of calibration data. Charge spreading due to illumination of small spots with high photon rates is discussed with respect to the charge handling capacity of a pixel and the effect of the charge spreading process on the resulting signal patterns.
© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
N. Kimmel, R. Andritschke, L. Englert, S. Epp, A. Hartmann, R. Hartmann, G. Hauser, P. Holl, I. Ordavo, R. Richter, L. Strüder, and J. Ullrich "Calibration methods and performance evaluation for pnCCDs in experiments with FEL radiation", Proc. SPIE 8078, Advances in X-ray Free-Electron Lasers: Radiation Schemes, X-ray Optics, and Instrumentation, 80780V (20 May 2011); https://doi.org/10.1117/12.887026
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Electrons

Calibration

Free electron lasers

Charge-coupled devices

X-rays

Sensors

Spectroscopy

RELATED CONTENT

Report on the eROSITA camera system
Proceedings of SPIE (July 24 2014)
Physical model of the charge transfer loss of the pn...
Proceedings of SPIE (October 22 1999)
Non-Gaussian noise in x-ray and gamma-ray detectors
Proceedings of SPIE (April 20 2005)
CUBIC: preflight calibration status
Proceedings of SPIE (September 01 1995)

Back to Top