Paper
27 June 1988 Comparison Of 3-D Tomographic Algorithms For Vascular Reconstruction
A. Rougee, K. M. Hanson, D. Saint-Felix
Author Affiliations +
Abstract
We make a comparison of the performances of various three-dimensional reconstruction algorithms for situations where only few conic projections of a vascular tree are available. This problem is ill-posed and prior information must therefore be used to regularize the solution. We restrict ourselves to methods that are able to handle the sparseness and the non-negativity that caracterize a iodinated vascular structure: the Extreme Value Technique and related methods, and the Algebraic Reconstruction Technique. The results we obtained led us to derive a new method based on a two steps detection-estimation scheme.
© (1988) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
A. Rougee, K. M. Hanson, and D. Saint-Felix "Comparison Of 3-D Tomographic Algorithms For Vascular Reconstruction", Proc. SPIE 0914, Medical Imaging II, (27 June 1988); https://doi.org/10.1117/12.968659
Lens.org Logo
CITATIONS
Cited by 10 scholarly publications and 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Reconstruction algorithms

Medical imaging

Holmium

Signal attenuation

Statistical analysis

Error analysis

Detection and tracking algorithms

Back to Top