Paper
28 July 2014 Testing fully depleted CCD
Author Affiliations +
Abstract
The focal plane of the PAU camera is composed of eighteen 2K x 4K CCDs. These devices, plus four spares, were provided by the Japanese company Hamamatsu Photonics K.K. with type no. S10892–04(X). These detectors are 200 μm thick fully depleted and back illuminated with an n-type silicon base. They have been built with a specific coating to be sensitive in the range from 300 to 1,100 nm. Their square pixel size is 15 μm. The read-out system consists of a Monsoon controller (NOAO) and the panVIEW software package. The deafualt CCD read-out speed is 133 kpixel/s. This is the value used in the calibration process. Before installing these devices in the camera focal plane, they were characterized using the facilities of the ICE (CSIC– IEEC) and IFAE in the UAB Campus in Bellaterra (Barcelona, Catalonia, Spain). The basic tests performed for all CCDs were to obtain the photon transfer curve (PTC), the charge transfer efficiency (CTE) using X-rays and the EPER method, linearity, read-out noise, dark current, persistence, cosmetics and quantum efficiency. The X-rays images were also used for the analysis of the charge diffusion for different substrate voltages (VSUB). Regarding the cosmetics, and in addition to white and dark pixels, some patterns were also found. The first one, which appears in all devices, is the presence of half circles in the external edges. The origin of this pattern can be related to the assembly process. A second one appears in the dark images, and shows bright arcs connecting corners along the vertical axis of the CCD. This feature appears in all CCDs exactly in the same position so our guess is that the pattern is due to electrical fields. Finally, and just in two devices, there is a spot with wavelength dependence whose origin could be the result of a defectous coating process.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ricard Casas, Laia Cardiel-Sas, Francisco J. Castander, Jorge Jiménez, and Juan de Vicente "Testing fully depleted CCD", Proc. SPIE 9147, Ground-based and Airborne Instrumentation for Astronomy V, 91472R (28 July 2014); https://doi.org/10.1117/12.2054717
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Charge-coupled devices

Quantum efficiency

X-rays

Cameras

Electronics

Calibration

Sensors

RELATED CONTENT

Soft X-ray Imager (SXI) onboard ASTRO-H
Proceedings of SPIE (July 29 2014)
Soft x ray response of x ray CCD camera XIS...
Proceedings of SPIE (October 11 2004)
CUBIC x ray CCD spectroscopy of the diffuse x...
Proceedings of SPIE (September 01 1995)
CUBIC: preflight calibration results and initial operations
Proceedings of SPIE (October 31 1996)
Flight CCD selection for the x ray CCD camera of...
Proceedings of SPIE (February 03 2004)
Ground calibration of the XMM EPIC MOS cameras at the...
Proceedings of SPIE (October 22 1999)
CUBIC: preflight calibration status
Proceedings of SPIE (September 01 1995)

Back to Top