Paper
23 July 2014 AQUARIUS: the next generation mid-IR detector for ground-based astronomy, an update.
Author Affiliations +
Abstract
ESO has already published data from a preliminary laboratory analysis on the new mid-IR detector, AQUARIUS, at the previous SPIE conference of 2012, held in Amsterdam2. This data analysis indicated that this new mid-IR Si:As IBC detector, from Raytheon Vision Systems, was an excellent astronomical detector when compared to previous generations of this detector type, specifically in terms of stability, read noise and cosmetic quality. Since that time, the detector has been deployed into the VISIR1 instrument at the VLT, with very mixed performance results, especially when used with the telescope secondary mirror, to chop between two areas of sky to do background subtraction and at the same time when many frames are co-added to improve the signal to noise performance. This is the typical mode of operation for a mid-IR instrument on a ground based telescope. Preliminary astronomical data analysis indicated that the new detector was a factor of two to three times less sensitive in terms of its signal to noise per unit time performance when directly compared to the old DRS detector that AQUARIUS was designed to replace. To determine the reason for this loss of sensitivity, the instrument was removed from the telescope and not offered to the ESO user community. A detector testing campaign was then initiated in our laboratory to determine the reasons for this loss of sensitivity, assuming that it was an issue with the new detector itself. This paper reports on our latest laboratory measurements to determine the reasons for this loss of sensitivity. We specifically report on indirect measurements made to measure the quantum efficiency of the detector, which can be difficult to measure directly. We also report on a little known source of noise, called Excess Low Frequency Noise (ELFN). Detailed analysis and testing has confirmed that this ELFN is the reason for the loss of instrument sensitivity. This has been proven by a re-commissioning phase at the telescope with the instrument and the detector. A new set of observing parameters and observational regime have been developed to help to mitigate the ELFN. We outline a possible explanation for the source of the EFLN, learnt from a literature search and discussion with the manufacturer.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Derek Ives, Gert Finger, Gerd Jakob, and Udo Beckmann "AQUARIUS: the next generation mid-IR detector for ground-based astronomy, an update.", Proc. SPIE 9154, High Energy, Optical, and Infrared Detectors for Astronomy VI, 91541J (23 July 2014); https://doi.org/10.1117/12.2055837
Lens.org Logo
CITATIONS
Cited by 7 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Telescopes

Mid-IR

Astronomy

Quantum efficiency

Mirrors

Doping

RELATED CONTENT

Surface features in U band of ITL devices for the...
Proceedings of SPIE (December 13 2020)
Development of a cold chopper for TAO/MIMIZUKU
Proceedings of SPIE (December 13 2020)
A new mid infrared camera for ground based 30 micron...
Proceedings of SPIE (July 09 2008)
Development of MIMIZUKU a mid infrared multi field imager...
Proceedings of SPIE (September 24 2012)
MANIAC a new mid and near infrared array...
Proceedings of SPIE (October 23 1997)
Further Tests Of The GE 32 X 1 InSb CID...
Proceedings of SPIE (November 08 1984)

Back to Top