2 June 2014 A comparison of defect size and film quality obtained from Film digitized image and digital image radiographs
Poramate Kamlangkeng, Prateepasen Asa, Noipitak Mai
Author Affiliations +
Proceedings Volume 9234, International Conference on Experimental Mechanics 2013 and Twelfth Asian Conference on Experimental Mechanics; 92340V (2014) https://doi.org/10.1117/12.2054335
Event: International Conference on Experimental Mechanics 2013 and the Twelfth Asian Conference on Experimental Mechanics, 2013, Bangkok, Thailand
Abstract
Digital radiographic testing is an acceptable premature nondestructive examination technique. Its performance and limitation comparing to the old technique are still not widely well known. In this paper conducted the study on the comparison of the accuracy of the defect size measurement and film quality obtained from film and digital radiograph techniques by testing in specimens and known size sample defect. Initially, one specimen was built with three types of internal defect; which are longitudinal cracking, lack of fusion, and porosity. For the known size sample defect, it was machined various geometrical size for comparing the accuracy of the measuring defect size to the real size in both film and digital images. To compare the image quality by considering at smallest detectable wire and the three defect images. In this research used Image Quality Indicator (IQI) of wire type 10/16 FE EN BS EN-462-1-1994. The radiographic films were produced by X-ray and gamma ray using Kodak AA400 size 3.5x8 inches, while the digital images were produced by Fuji image plate type ST-VI with 100 micrometers resolution. During the tests, a radiator GE model MF3 was implemented. The applied energy is varied from 120 to 220 kV and the current from 1.2 to 3.0 mA. The intensity of Iridium 192 gamma ray is in the range of 24-25 Curie. Under the mentioned conditions, the results showed that the deviation of the defect size measurement comparing to the real size obtained from the digital image radiographs is below than that of the film digitized, whereas the quality of film digitizer radiographs is higher in comparison.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Poramate Kamlangkeng, Prateepasen Asa, and Noipitak Mai "A comparison of defect size and film quality obtained from Film digitized image and digital image radiographs", Proc. SPIE 9234, International Conference on Experimental Mechanics 2013 and Twelfth Asian Conference on Experimental Mechanics, 92340V (2 June 2014); https://doi.org/10.1117/12.2054335
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image quality

Digital imaging

Radiography

Gamma radiation

X-rays

Image fusion

Digital image processing

Back to Top