29 March 2016 Grid-less imaging with antiscatter correction software in 2D mammography: the effects on image quality and MGD under a partial virtual clinical validation study
Author Affiliations +
Abstract
This work investigated the effect of the grid-less acquisition mode with scatter correction software developed by Siemens Healthcare (PRIME mode) on image quality and mean glandular dose (MGD) in a comparative study against a standard mammography system with grid. Image quality was technically quantified with contrast-detail (c-d) analysis and by calculating detectability indices (d’) using a non-prewhitening with eye filter model observer (NPWE). MGD was estimated technically using slabs of PMMA and clinically on a set of 11439 patient images. The c-d analysis gave similar results for all mammographic systems examined, although the d’ values were slightly lower for the system with PRIME mode when compared to the same system in standard mode (-2.8% to -5.7%, depending on the PMMA thickness). The MGD values corresponding to the PMMA measurements with automatic exposure control indicated a dose reduction from 11.0% to 20.8% for the system with PRIME mode compared to the same system without PRIME mode. The largest dose reductions corresponded to the thinnest PMMA thicknesses. The results from the clinical dosimetry study showed an overall population-averaged dose reduction of 11.6% (up to 27.7% for thinner breasts) for PRIME mode compared to standard mode for breast thicknesses from 20 to 69 mm. These technical image quality measures were then supported using a clinically oriented study whereby simulated clusters of microcalcifications and masses were inserted into patient images and read by radiologists in an AFROC study to quantify their detectability. In line with the technical investigation, no significant difference was found between the two imaging modes (p-value 0.95).
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Nelis Van Peteghem, Frédéric Bemelmans, Xenia Bramaje Adversalo, Elena Salvagnini, Nicholas Marshall, Hilde Bosmans, and Chantal Van Ongeval "Grid-less imaging with antiscatter correction software in 2D mammography: the effects on image quality and MGD under a partial virtual clinical validation study", Proc. SPIE 9783, Medical Imaging 2016: Physics of Medical Imaging, 97832K (29 March 2016); https://doi.org/10.1117/12.2216690
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Polymethylmethacrylate

Breast

Image quality

Image quality standards

Mammography

Clinical trials

Imaging systems

Back to Top