25 July 2016 The hard x-ray imager (HXI) onboard ASTRO-H
Kazuhiro Nakazawa, Goro Sato, Motohide Kokubun, Teruaki Enoto, Yasushi Fukazawa, Kouichi Hagino, Atsushi Harayama, Katsuhiro Hayashi, Jun Kataoka, Junichiro Katsuta, Philippe Laurent, François Lebrun, Olivier Limousin, Kazuo Makishima, Tsunefumi Mizuno, Kunishiro Mori, Takeshi Nakamori, Toshio Nakano, Hirofumi Noda, Hirokazu Odaka, Masanori Ohno, Masayuki Ohta, Shinya Saito, Rie Sato, Hiroyasu Tajima, Hiromitsu Takahashi, Tadayuki Takahashi, Shin'ichiro Takeda, Yukikatsu Terada, Hideki Uchiyama, Yasunobu Uchiyama, Shin Watanabe, Kazutaka Yamaoka, Yoichi Yatsu, Takayuki Yuasa
Author Affiliations +
Abstract
Hitomi X-ray observatory launched in 17 February 2016 had a hard X-ray imaging spectroscopy system made of two hard X-ray imagers (HXIs) coupled with two hard X-ray telescopes (HXTs). With 12 m focal length, they provide fine (2' half-power diameter; HPD) imaging spectroscopy at 5 to 80 keV. The HXI main imagers are made of 4 layers of Si and a CdTe semiconductor double-sided strip detectors, stacked to enhance detection efficiency as well as to enable photon interaction-depth sensing. Active shield made of 9 BGO scintillators surrounds the imager to provide with low background. Following the deployment of the Extensible Optical Bench (EOB) on 28 February, the HXI was gradually turned on. Two imagers successfully started observation on 14 March, and was operational till the incident lead to Hitomo loss, on 26 March. All detector channels, 1280 ch of imager and 11 channel of active shields and others each, worked well and showed performance consistent with those seen on ground. From the first light observation of G21.5-0.9 and the following Crab observations, 5-80 keV energy coverage and good detection efficiency were confirmed. With blank sky observations, we checked our background level. In some geomagnetic region, strong background continuum, presumably caused by trapped electron with energy ~100 keV, is seen. But by cutting the high-background time-intervals, the background became significantly lower, typically with 1-3 x 10-4 counts s-1 keV-1 cm-2 (here cm2 is shown with detector geometrical area). Above 30 keV, line and continuum emission originating from activation of CdTe was significantly seen, though the level of 1-4 x 10-4 counts s-1 keV-1 cm-2 is still comparable to those seen in NuSTAR. By comparing the effective area and background rate, preliminary analysis shows that the HXI had a statistical sensitivity similar to NuSTAR for point sources, and more than twice better for largely extended sources.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Kazuhiro Nakazawa, Goro Sato, Motohide Kokubun, Teruaki Enoto, Yasushi Fukazawa, Kouichi Hagino, Atsushi Harayama, Katsuhiro Hayashi, Jun Kataoka, Junichiro Katsuta, Philippe Laurent, François Lebrun, Olivier Limousin, Kazuo Makishima, Tsunefumi Mizuno, Kunishiro Mori, Takeshi Nakamori, Toshio Nakano, Hirofumi Noda, Hirokazu Odaka, Masanori Ohno, Masayuki Ohta, Shinya Saito, Rie Sato, Hiroyasu Tajima, Hiromitsu Takahashi, Tadayuki Takahashi, Shin'ichiro Takeda, Yukikatsu Terada, Hideki Uchiyama, Yasunobu Uchiyama, Shin Watanabe, Kazutaka Yamaoka, Yoichi Yatsu, and Takayuki Yuasa "The hard x-ray imager (HXI) onboard ASTRO-H", Proc. SPIE 9905, Space Telescopes and Instrumentation 2016: Ultraviolet to Gamma Ray, 990511 (25 July 2016); https://doi.org/10.1117/12.2231176
Lens.org Logo
CITATIONS
Cited by 7 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Hard x-rays

Imaging systems

Avalanche photodetectors

Satellites

Cameras

Calibration

RELATED CONTENT

The Hard X ray Imager (HXI) for the ASTRO H...
Proceedings of SPIE (July 31 2014)
Performance of ASTRO-H hard x-ray telescope (HXT)
Proceedings of SPIE (July 18 2016)
The Hard X ray Imager (HXI) for the ASTRO H...
Proceedings of SPIE (September 17 2012)
The MIRAX x-ray astronomy transient mission
Proceedings of SPIE (June 13 2006)
PN CCD camera for XMM and ABRIXAS design of...
Proceedings of SPIE (October 22 1999)
Hard x-ray imager (HXI) for the ASTRO-H Mission
Proceedings of SPIE (July 29 2010)

Back to Top