We report a linear cavity all-fiber passive Q-switched thulium-doped fiber laser operating at the 2 μm wavelength range. The laser configuration is based on a thulium-doped fiber used as a gain medium and an unpumped segment of holmium-doped fiber which acts as a fiber saturable absorber. The cavity is formed by a fiber optical loop mirror and the flat end facet of the holmium-doped fiber. The fiber segments as saturable absorber is a 1-m long single mode doubleclad holmium-doped fiber. Q-switched pulses are obtained at the wavelength of 2024.5 nm with a pulse width of 1.1 μs. The pulse repetition rate increases as a linear function of the applied pump power. The maximum pulse repetition rate of 100 kHz was obtained with a pump power of 2.4 W.
We report a linear cavity all-fiber Thulium-doped fiber (TDF) laser with tunable narrow linewidth operating near to 2 μm of wavelength. The TDF is pumped with a laser source at 1567 nm. The cavity is delimited by two fiber optical loop mirrors (FOLM) with high birefringence fiber in the loop (Hi-Bi FOLM) with different periodical wavelength-dependent reflection periods. The wavelength tuning range for the generated laser line of ~44.3 nm depends on the Hi-Bi FOLM with long wavelength period of 54.4 nm. The generated laser spectral width, less than 0.05 nm, is determined by the Hi- Bi FOLM with narrow-band wavelength period of 1 nm. Discrete wavelength tuning is achieved by wavelength reflection displacement of the narrow-band Hi-Bi FOLM by temperature variation on the high birefringence fiber loop. The temperature changes are performed with a temperature electronic controller/meter with resolution of 0.06°C in a temperature range from 22.87 to 49.12°C. Dual-wavelength generation with a wavelengths separation of ~47 nm is also obtained at the single wavelength tuning limits.
We present experimental results of a proposed dual wavelength fiber laser with Er/Yb double clad fiber. The linear cavity laser is based in the use of two fiber Bragg gratings for wavelength selection and a Sagnac interferometer for cavity losses adjustment to obtain dual-wavelength operation. With pump power variations from the lasing threshold to 890 mW. Self-Q-switched pulses are obtained. With a pump power range from 1.1 W to 1.7 W, self-pulsing operation is observed. With pump power above 2 W CW operation is achieved.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.