The Keck Planet Imager and Characterizer (KPIC) instrument at the Keck Observatory consists of a series of upgrades to the Keck II Adaptive Optics system and the NIRSPEC spectrograph to enable diffraction-limited, high-resolution (R∼35, 000) spectroscopy, originally in the K (∼2.0−2.5 μm) and L (∼3.2−3.7 μm) bands only. Phase I consisted of single-mode fiber injection/extraction units used in conjunction with an H band pyramid wavefront sensor. Using single-mode fibers provides a gain in stellar rejection, a substantial reduction in sky background, and a stable, well-defined line-spread function on the spectrograph. In 2022, Phase II brought a 1000-actuator deformable mirror, beam-shaping optics, a vortex fiber nulling mode, and more.
In this paper we present the results of the latest upgrades to the KPIC instrument. Among these upgrades, a second fiber bundle with related injection/extraction optics and new dichroics were added to extend KPIC’s science capabilities to y through H band, and to provide access to laser frequency combs for spectral calibration from y-K. Additionally, the charge 2 vortex mask for fiber nulling was supplemented with a charge 1 mask to enable spectroscopy of low mass companions at very small angular separations. Other upgrades included an atmospheric dispersion corrector, a new calibration source switching system, and an optimized tip/tilt control system. Here we show preliminary results of on-sky tests performed in the first few months of re-commissioning, along with the next steps for the instrument.
The Keck Planet Imager and Characterizer (KPIC), a series of upgrades to the Keck II Adaptive Optics System and Instrument Suite, aims to demonstrate high-resolution spectroscopy of faint exoplanets that are spatially resolved from their host stars. In this paper, we measure KPIC’s sensitivity to companions as a function of separation (i.e., the contrast curve) using on-sky data collected over four years of operation. We show that KPIC is able to reach contrasts of 1.3 × 10−4 at 90 mas and 9.2 × 10−6 at 420 mas separation from the star, and that KPIC can reach planet-level sensitivities at angular separations within the inner working angle of coronagraphic instruments such as GPI and SPHERE. KPIC is also able to achieve more extreme contrasts than other medium-/high-resolution spectrographs that are not as optimized for high-contrast performance. We decompose the KPIC performance budget into individual noise terms and discuss limiting factors. The fringing that results from combining a high-contrast imaging system with a high-resolution spectrograph is identified as an important source of systematic noise. After mitigation and correction, KPIC is able to reach within a factor of 2 of the photon noise limit at separations < 200 mas. At large separations, KPIC is limited by the background noise performance of NIRSPEC.
The Keck Planet Imager and Characterizer (KPIC) combines high contrast imaging with high resolution spectroscopy (R∼35,000 in K band) to study directly imaged exoplanets and brown dwarfs in unprecedented detail. KPIC aims to spectrally characterize substellar companions through measurements of planetary radial velocities, spins, and atmospheric composition. Currently, the dominant source of systematic noise for KPIC is fringing, or oscillations in the spectrum as a function of wavelength. The fringing signal can dominate residuals by up to 10% of the continuum for high S/N exposures, preventing accurate wavelength calibration, retrieval of atmospheric parameters, and detection of planets with flux ratios less than 1% of the host star. To combat contamination from fringing, we first identify its three unique sources and adopt a physically informed model of Fabry-Pérot cavities to apply to post-processed data. We find this strategy can effectively model the fringing in observations of bright stars, reducing the residual systematics caused by fringing by a factor of 2. Next, we wedge two of the transmissive optics internal to KPIC to eliminate two sources of fringing and confirm the third source as the entrance window to the spectrograph. Finally, we apply our previous model of the Fabry-Pérot cavity to new data taken with the wedged optics to reduce the amplitude of the residuals by a factor of 10.
Vortex fiber nulling (VFN) is a single-aperture interferometric technique for detecting and characterizing exoplanets separated from their host star by less than a diffracted beam width. VFN uses a vortex mask and single-mode fiber to selectively reject starlight while coupling off-axis planet light with a simple optical design that can be readily implemented on existing direct imaging instruments that can feed light to an optical fiber. With its axially symmetric coupling region peaking within the inner working angle of conventional coronagraphs, VFN is more efficient at detecting new companions at small separations than conventional direct imaging, thereby increasing the yield of on-going exoplanet search campaigns. We deployed a VFN mode operating in K band (2.0 to 2.5 μm) on the Keck Planet Imager and Characterizer (KPIC) instrument at the Keck II Telescope. We present the instrument design of this first on-sky demonstration of VFN and the results from on-sky commissioning, including planet and star throughput measurements and predicted flux-ratio detection limits for close-in companions. The instrument performance is shown to be sufficient for detecting a companion 103 times fainter than a fifth magnitude host star in 1 h at a separation of 50 mas (1.1 λ / D). This makes the instrument capable of efficiently detecting substellar companions around young stars. We also discuss several routes for improvement that will reduce the required integration time for a detection by a factor >3.
The Keck Planet Imager and Characterizer (KPIC) is an instrument at the Keck II telescope that enables high-resolution spectroscopy of directly imaged exoplanets and substellar companions. KPIC uses single-mode fibers to couple the adaptive optics system to Keck’s near-infrared spectrometer (NIRSPEC). However, KPIC’s sensitivity at small separations is limited by the leakage of stellar light into the fiber. Speckle nulling uses a deformable mirror (DM) to destructively interfere starlight with itself, a technique typically used to reduce stellar signal on a focal-plane imaging detector. We present the first on-sky demonstration of speckle nulling through an optical fiber with KPIC, using NIRSPEC to collect exposures that measure speckle phase for quasi-real-time wavefront control while also serving as science data. We repeat iterations of measurement and correction, each using at least five exposures (four with DM probes to determine phase and one unprobed exposure to measure the intensity) and taking about 6 min when using 59.0 s exposures, including NIRSPEC overheads. We show a decrease in the on-sky leaked starlight by a factor of 2.6 to 2.8 in the targeted spectral order, at a spatial separation of 2.0 λ / D in K-band. This corresponds to an estimated factor of 2.6 to 2.8 decrease in the required exposure time to reach a given signal-to-noise ratio, relative to conventional KPIC observations. The performance of speckle nulling is limited by instability in the speckle phase: when the loop is opened, the null-depth degrades by a factor of 2 on the timescale of a single phase measurement, which would limit the suppression that can be achieved. Future work includes exploring gradient-descent methods, which may be faster and thereby able to achieve deeper nulls. In the meantime, the speckle nulling algorithm demonstrated in this work can be used to decrease stellar leakage and improve the signal-to-noise of science observations.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.