X-ray Phase-Contrast Computed Tomography (PC-CT) increases contrast in weakly attenuating samples, such as soft tissues. In Edge-Illumination (EI) PC-CT, phase effects are accessed from amplitude modulation of the x-ray beam using alternating transmitting and attenuating masks placed prior to the sample and detector. A large field of view PC-CT scanner using this technique was applied to two areas of cancer assessment, namely excised breast and esophageal tissue. For the breast tissue, Wide Local Excisions (WLEs) were studied intra-operatively using PC-CT for the evaluation of tumor removal in breast conservation surgery. Images were acquired in 10 minutes without compromising on image quality, showing this can be used in a clinical setting. Longer, higher resolution PC-CT images were also taken, with analysis showing previously undetected thinning of tumor strands. This would allow a second use of the system for “virtual histopathology”, outside of surgery. For the esophagus samples, tissues were taken from esophagectomy surgery, where the lower part of the esophagus is removed, and the stomach relocated. For the assessment of ongoing therapy, accurate staging of tumors in the removed esophagus is essential, with the current gold standard provided by histopathology. PCCT images were acquired on several samples and compare well with histopathology, with both modalities showing similar features. Examples are shown where staging of tumor penetration is possible with PC-CT images alone, which is hoped will be an important step in performing the imaging and staging intra-operatively.
A preliminary investigation into the use of cycloidal computed tomography for intraoperative specimen imaging is presented. Intraoperative imaging is applied in time-sensitive clinical settings, where obtaining a high-resolution, highquality image within minutes is paramount in evaluating the success of operations and/or the need for additional surgery. As a flexible imaging method that is compatible with x-ray phase contrast imaging, cycloidal computed tomography can provide both high spatial resolution and high image contrast, whilst keeping scan times short thanks to an effective under-sampling approach. To gather early evidence, the method was tested on resected breast and oesophageal tissue. The results, although preliminary, indicate that cycloidal imaging may indeed be beneficial for intraoperative specimen imaging, although further studies are required to confirm this potential.
Owing to their combination of low weight and high strength, carbon fiber reinforced composites are widely used in the aerospace industry, including for primary aircraft structures. Porosity introduced by the manufacturing process can compromise structural performance and integrity, with a maximum porosity content of 2% considered acceptable for many aerospace applications. The main nondestructive evaluation (NDE) techniques used in industry are ultrasonic imaging and X-ray computed tomography, however both techniques have limitations. Edge Illumination X-ray Phase Contrast Imaging (EI XPCi) is a novel technique that exploits the phase effects induced by damage and porosity on the X-ray beam to create improved contrast. EI XPCi is a differential (i.e., sensitive to the first derivative of the phase), multi-modal phase method that uses a set of coded aperture masks to acquire and retrieve the absorption, refraction, and ultra-small-angle scattering signals, the latter arising from sub-pixel sample features. For carbon fiber-reinforced woven composite specimens with varying levels of porosity, porosity quantification obtained through various signals produced by EI XPCi was compared to ultrasonic immersion absorption C-scans and matrix digestion. The standard deviation of the differential phase is introduced as a novel signal for the quantification of porosity in composite plates, with good correlation to ultrasonic attenuation.
Combining low weight and high strength, carbon fiber reinforced composites are widely used in the aerospace industry, including for primary aircraft structures. Barely visible impact damage can compromise the structural integrity and potentially lead to failures. Edge Illumination (EI) X-ray Phase Contrast imaging (XPCi) is a novel X-ray imaging technique that uses the phase effects induced by damage to create improved contrast. For a small cross-ply composite specimen with impact damage, damage detection was compared to ultrasonic immersion C-scans. Different defect types could be located and identified, verified from the conventional ultrasonic NDE measurement.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.