OTIS has recently undergone cryogenic vacuum testing in Chamber A at Johnson Space Center in Houston, TX. A key outcome of this test was to verify there is adequate range of motion in PMSA and SMA actuators to align them to AOS/ISIM under flight-like conditions. The alignment state of the PMSAs and SMA was measured using photogrammetry and cross-checked optically using a variation of a classical Hartmann test. In the “Pass-and-a-Half” (PAAH) configuration, fiber sources near the Cassegrain focus propagate light through the full optical train and small tilts on the PMSAs create an array of spots on the science instrument detectors, mimicking the effect of a Hartmann mask. Comparison of measured and modeled spot arrays provides the alignment state of the SMA and the global tilt of the primary mirror. This paper will discuss the methodology, testing, and analysis performed to measure the alignment state of OTIS using the Hartmann method and verify the primary and secondary mirrors can be successfully aligned on orbit to meet performance requirements.