We are developing monolithic active pixel sensors, x-ray SOIPIXs based on a Silicon-On-Insulator CMOS technology. Its event trigger output function offers a high time resolution better than ~10 usec. (1) In 2022-23, we and evaluated large sensors, XRPIX-X, with a pixel array size of 14mm x 22mm. We report its design and the results of the performance evaluation. (2) We are developing "Digital X-ray SOIPIXs" for satellite use, featuring on-chip ADCs, DACs, and BGRs for noise robustness. An on-chip clock pattern generator is also included to simplify the readout digital circuits. (3) XRPIXs are increasingly being utilized in various scientific applications beyond x-ray astronomy, and a brief introduction will be provided.
We are developing x-ray Silicon-On-Insulator (SOI) pixel sensors, called "XRPIX" for the next generation x-ray astronomy satellites. The XRPIX has the unique function of event trigger and hit address outputs allowing us to read out signals only from the x-ray detected pixels. In order to use the XRPIX for the x-ray observatories, the sufficient time resolution is required to discriminate non x-ray events using the anti-coincidence method. For this method, a hit trigger of the XRPIX with a short delay and jitter time (~10μs) is required since the typical hitting rate of the high-energy background events on active shields is ~10kHz. Therefore, we have evaluated the trigger performance using the laser-generated pseudo-x-ray instead of x-ray sources. This allows us to easily control the timing, the position, and the energy of the hit events on the XRPIX. We estimated trigger's delay and jitter time to be ≲1μs. Here, we will report on the results of the trigger evaluation.
We evaluate the single event tolerance of the x-ray silicon-on-insulator (SOI) pixel sensor named XRPIX, developed for the future x-ray astronomical satellite FORCE. In this work, we measure the cross-section of single event upset (SEU) of the shift register on XRPIX by irradiating heavy ion beams with linear energy transfer (LET) ranging from 0.022 to 68 MeV / ( mg/cm2 ) . From the SEU cross-section curve, the saturation cross-section and threshold LET are successfully obtained to be 3.4−0.9+2.9×10−10 cm2/bit and 7.3−3.5+1.9 MeV/(mg/cm2), respectively. Using these values, the SEU rate in orbit is estimated to be ≲ 0.1 event / year primarily due to the secondary particles induced by cosmic-ray protons. This SEU rate of the shift register on XRPIX is negligible in the FORCE orbit.
We have been developing monolithic active pixel sensors, X-ray SOIPIXs based on a Silicon-On-Insulator CMOS technology. Its event trigger output function offers a high time resolution better than ~10 usec. (1) We report the device structure optimized to achieve both low noise, a thick depletion layer, and to non-punch-through. (2) We succeeded in achieving an energy resolution of ~300 eV (FWHM) at 6 keV with a depletion layer of 300 um at room temperature by operating frequent reset to reduce the shot noise. (3) We present the development of "Digital X-ray SOIPIXs" having on-chip ADCs, DACs and readout sequencers.
We have been developing the monolithic active pixel detector XRPIX onboard the future x-ray astronomical satellite FORCE. XRPIX is composed of complementary metal-oxide-semiconductor pixel circuits, SiO2 insulator, and Si sensor by utilizing the silicon-on-insulator (SOI) technology. When the semiconductor detector is operated in orbit, it suffers from radiation damage due to x-rays emitted from celestial objects as well as cosmic rays. From previous studies, positive charges trapped in the SiO2 insulator are known to cause degradation of the detector performance. To improve the radiation hardness, we developed XRPIX equipped with a double-SOI (D-SOI) structure, introducing an additional silicon layer in the SiO2 insulator. This structure is aimed at compensating for the effect of the trapped positive charges. Although the radiation hardness of the D-SOI detectors to cosmic rays has been evaluated, the radiation effect due to x-ray irradiation has not been evaluated. Thus, we then conduct an x-ray irradiation experiment using an x-ray generator with a total dose of 10 krad at the SiO2 insulator, equivalent to 7 years in orbit. As a result of this experiment, the energy resolution in full-width half maximum for the 5.9 keV x-ray degrades by 17.8 % ± 2.8 % and the dark current increases by 89 % ± 13 % . We also investigate the physical mechanism of the increase in the dark current due to x-ray irradiation using technology computer-aided design simulation. It is found that the increase in the dark current can be explained by the increase in the interface state density at the Si / SiO2 interface.
X-ray silicon-on-insulator (SOI) pixel sensors, “XRPIX,” are being developed for the next-generation x-ray astronomical satellite, “FORCE.” The XRPIX is fabricated with the SOI technology, which makes it possible to integrate a high-resistivity Si sensor and a low-resistivity Si complementary metal oxide semiconductor (CMOS) circuit. The CMOS circuit in each pixel is equipped with a trigger function, allowing us to read out outputs only from the pixels with x-ray signals at the timing of x-ray detection. This function thus realizes high throughput and high time resolution, which enables to employ anti-coincidence technique for background rejection. A new series of XRPIX named XRPIX6E developed with a pinned depleted diode (PDD) structure improves spectral performance by suppressing the interference between the sensor and circuit layers. When semiconductor x-ray sensors are used in space, their spectral performance is generally degraded owing to the radiation damage caused by high-energy protons. Therefore, before using an XRPIX in space, it is necessary to evaluate the extent of degradation of its spectral performance by radiation damage. Thus, we performed a proton irradiation experiment for XRPIX6E for the first time at Heavy Ion Medical Accelerator in Chiba in the National Institute of Radiological Sciences. We irradiated XRPIX6E with high-energy protons with a total dose of up to 40 krad, equivalent to 400 years of irradiation in orbit. The 40-krad irradiation degraded the energy resolution of XRPIX6E by 25 ± 3 % , yielding an energy resolution of 260.1 ± 5.6 eV at the full-width half maximum for 5.9 keV X-rays. However, the value satisfies the requirement for FORCE, 300 eV at 6 keV, even after the irradiation. It was also found that the PDD XRPIX has enhanced radiation hardness compared to previous XRPIX devices. In addition, we investigated the degradation of the energy resolution; it was shown that the degradation would be due to increasing energy-independent components, e.g., readout noise.
We are developing an X-ray SOI pixel detector “XRPIX” for the next generation X-ray astronomical satellite “FORCE”. XRPIX is the detector using SOI (Silicon-On-Insulator) technology which makes it possible to integrate a high-resistivity Si sensor part and a low-resistivity Si CMOS circuit part. The CMOS circuit is equipped with the trigger function, which can read out only the output signal of the pixel where the X-ray is incident. This function realizes high throughput and high time resolution, enabling the background rejection with anticoincidence technique. A new series of XRPIX named XRPIX6E, we developed, with a Pinned Depleted Diode (PDD) structure improves the spectral performance by suppressing the interference between the sensor layer and the circuit layer. When semiconductor X-ray detectors are used in space, it is known that their spectral performance is degraded due to radiation damage caused by high-energy protons. Therefore, before using XRPIX in space, it is necessary to evaluate how much the spectral performance will be degraded by radiation damage. Then we performed proton irradiation experiment for XRPIX6E for the first time at HIMAC in National Institute of Radiological Sciences. We irradiated XRPIX with high-energy protons up to a total dose of 40 krad, equivalent to 400 years irradiation in orbit. As a result, the energy resolution in full width half maximum at the 5:9 keV degrades by 25 ± 3%, however, is better than the required performance of FORCE, 300 eV at 6 keV. It was also found that the PDD structure XRPIX has better radiation hardness than the previous XRPIX series. In addition, We investigated about the degradation of the energy resolution; it was found that the degradation would be due to increasing energy independent components, for example, readout noise.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.