This study reports the results of active thermography non-destructive inspection of an ancient artwork. The artwork was decorated with metal ornaments, realized by hands from specialized craftsmen. However, it was seriously damaged by a catastrophic event based on repeated vibrations. The condition of the ancient artwork was evaluated from thermal data recorded during and after a long pulse heating. In this study, the evaluations were performed using not only the raw thermograms but also the results of three post-processing algorithms, namely: pulsed phase thermography (PPT), thermographic signal reconstruction (TSR), and principal component thermography (PCT). Comparison of the results based on signal-to-noise ratio (SNR) calculations showed that TSR was the most effective technique for detecting defects, and PCT was also effective for the detection of crack-shaped defects. In contrast, PPT seems not suitable for inspection of objects with a complex shape.
Exercise induced muscle damage (EIMD), is usually experienced in i) humans who have been physically inactive for prolonged periods of time and then begin with sudden training trials and ii) athletes who train over their normal limits. EIMD is not so easy to be detected and quantified, by means of commonly measurement tools and methods. Thermography has been used successfully as a research detection tool in medicine for the last 6 decades but very limited work has been reported on EIMD area. The main purpose of this research is to assess and characterize EIMD, using thermography and image processing techniques. The first step towards that goal is to develop a reliable segmentation technique to isolate the region of interest (ROI). A semi-automatic image processing software was designed and regions of the left and right leg based on superpixels were segmented. The image is segmented into a number of regions and the user is able to intervene providing the regions which belong to each of the two legs. In order to validate the image processing software, an extensive experimental investigation was carried out, acquiring thermographic images of the rectus femoris muscle before, immediately post and 24, 48 and 72 hours after an acute bout of eccentric exercise (5 sets of 15 maximum repetitions), on males and females (20-30 year-old). Results indicate that the semi-automated approach provides an excellent bench-mark that can be used as a clinical reliable tool.
In the present research work a study was carried out evaluating the applicability of two NDT techniques, this of Transient Thermography (TT) and Ultrasonic Testing (UT) for the inspection of different types of composite materials (i.e. laminated CFRPs, laminated hybrid FRPs and sandwiched panels). The composite structures were consisted of a variety of artificial defects, while inspection was performed through different testing configurations. In particular, transient thermography was implemented through the monitoring of the surface transient cooling after flash heating the samples and ultrasonic testing was applied using both a conventional single element probe (immersion technique) and a linear phased array transducer consisted of 128 elements. The main objective of this work was to compare the applicability and effectiveness of the two techniques in aerospace composites inspection as well as to evaluate the accuracy produced regarding the quantitative characterisation of the detected features. The obtained results showed that all the defects were revealed by either transient thermography or ultrasonic testing, whilst thermographic inspection can display the acquired results in a more rapid manner. On the other hand UT testing can provide efficient results for deeper probing requiring however longer inspection times. In other words, the acquired data and the respective analyses highlighted the different capability of each testing configuration, to detect defects and to gain knowledge for the interior of the structures.
KEYWORDS: Signal to noise ratio, Thermography, Inspection, Defect detection, Signal processing, Visibility, Data acquisition, Image processing, Visualization, Image quality
In this study, three different CFRP specimens with internal artificial delaminations of various sizes and located at different depths were investigated by means of Pulsed Thermography (PT) under laboratory conditions. The three CFRP panels, having the same thickness and defects characteristics but with a different shape (planar, trapezoid and curved), were assessed after applying various signal processing tools on the acquired thermal data (i.e. Thermographic Signal Reconstruction, Pulsed Phase Thermography and Principal Component Thermography). The effectiveness of the above processing tools was initially evaluated in a qualitative manner, comparing the imaging outputs and the information retrieval in terms of defect detectability enhancement and noise reduction. Simultaneously, the produced defect detectability was evaluated through Signal-to-Noise Ratio (SNR) computations, quantifying the image quality and the intensity contrast produced between the defected area and the adjacent background area of the test panel. From the results of this study, it can be concluded that the implementation of PT along with the application of advanced signal processing algorithms can be a useful technique for NDT assessment, providing enhanced qualitative information. Nevertheless, SNR analysis showed that despite the enhanced visibility resulting from these algorithms, these can be properly applied in order to retrieve the best possible information according to the user’s demands.
KEYWORDS: General packet radio service, Radar, Bridges, Reflection, Data acquisition, Inspection, 3D acquisition, Ground penetrating radar, Data processing, Dielectrics
The present study evaluates the potential of GPR for the inspection of pre-stressed concrete bridges and its usefulness to provide non visible information of the interior structural geometry and condition, required for strengthening and rehabilitation purposes. For that purpose, different concrete blocks of varying dimensions with embedded steel reinforcement bars, tendon ducts and fabricated voids, were prepared and tested by means of GPR in a controlled laboratory environment. 2D data acquisition was carried out in reflection mode along single profile lines of the samples in order to locate the internal structural elements. 3D surveys were also performed in a grid format both along horizontal and vertical lines, and the individual profiles collected were interpolated and further processed using a 3D reconstruction software, in order to provide a detailed insight into the concrete structure. The obtained 2D profiles provided the accurate depth and position of the embedded rebars and tendon ducts, verifying the original drawings. 3D data cubes were created enabling the presentation of depth slices and providing additional information such as shape and localization of the internal elements. The results obtained from this work showed the effectiveness and reliability of the GPR technique for pre-stressed concrete bridge investigations.
The increasing deterioration of panel paintings can be due to physical processes that take place during exhibition or
transit, or as a result of temperature and humidity fluctuations within a building, church or museum. In response to
environmental alterations, a panel painting can expand or contract and a new equilibrium state is eventually reached.
These adjustments though, are usually accompanied by a change in shape in order to accommodate to the new
conditions. In this work, a holographic method for detecting detached regions and micro-cracks is described. Some of
these defects are confirmed by Thermographic Signal Reconstruction (TSR) technique. In addition, Pulsed Phase
Thermography (PPT) and Principal Component Thermography (PCT) allow to identify with greater contrast two
artificial defects in Mylar which are crucial to understand the topic of interest: the discrimination between defect
materials. Finally, traditional contact ultrasounds applications, are widely applied for the evaluation of the wood quality
in several characterization procedures. Inspecting the specimen from the front side, the natural and artificial defects of
the specimen are confirmed. Experimental results derived by the application of the integrated methods on an Italian panel
painting reproduction, called The Angel specimen, are presented. The main advantages that these techniques can offer to
the conservation and restoration of artworks are emphasized.
In thermography surveys, the inspector uses the camera to acquire images from the examined part. Common problems
are the lack of repeatability when trying to repeat the scanning process, the need to carry the equipment during
scanning, and long setting-up time. The aim of this paper is to present transient thermography results on CFRP plates
for assessing different types of fabricated defects (impact damage, inclusions for delaminations, etc), as well as and to
discuss and present a prototype robotic scanner to apply non destructive testing (thermographic scanning) on materials
and structures. Currently, the scanning process is not automatic. The equipment to be developed, will be able to perform
thermal NDT scanning on structures, create the appropriate scanning conditions (material thermal excitation), and
ensure precision and tracking of scanning process. A thermographic camera that will be used for the image acquisition
of the non destructive inspection, will be installed on a x, y, z, linear manipulator's end effector and would be
surrounded by excitation sources (optical lamps), required for the application of transient thermography. In this work
various CFRP samples of different shape, thickness and geometry were investigated using two different thermographic
systems in order to compare and evaluate their effectiveness concerning the internal defect detectability under different
testing conditions.
Smart methods for assessing the integrity of a composite structure are essential to both reduce manufacturing costs and
out of service time of the structure due to maintenance. Nowadays, thermal non-destructive testing (NDT) is commonly
used for assessing composites. This research work evaluates the potential of various infrared thermography (IRT)
approaches for assessing different types of fabricated defects (i.e. impact damage, inclusions for delaminations, etc) on
Glass Fibre Reinforced Polymer (GFRP) and Carbon Fibre Reinforced Polymer (CFRP) plates. Measurements were
performed using LWIR and three active approaches: a) pulsed thermography using the flash method (xenon flash
lamps), b) transient themography using IR-heating pulse, and c) thermographic inspection for cooled sample by freezing
in -20 °C and then use monitoring. Furthermore, integrated flash thermography by employing a MWIR system was also
used.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.