The recent advent of Optical Photothermal IR (O-PTIR), has enabled for the first time, submicron infrared microscopy in far-field reflection mode with the combination of Raman for simultaneous, correlative IR+Raman microscopy. These unique and exciting synergistic capabilities are now spawning interest in life science application [1-2]. A broad range of life science applications, otherwise impossible with traditional FTIR/QCL microscopy, will be presented, ranging from live cell imaging in water, to ultra-high resolution images of breast tissue calcifications, amyloid aggregates in neurons (neurites and dendritic spines), individual collagen fibrils with polarized IR and individual isotopically labelled bacterial cells and more.
Fourier transform infrared (FT-IR) chemical imaging has been demonstrated as a promising technique to complement histopathological assessment of biomedical tissue samples. Current histopathology practice involves preparing thin tissue sections and staining them using hematoxylin and eosin (H&E) after which a histopathologist manually assess the tissue architecture under a visible microscope. Studies have shown that there is disagreement between operators viewing the same tissue suggesting that a complementary technique for verification could improve the robustness of the evaluation, and improve patient care. FT-IR chemical imaging allows the spatial distribution of chemistry to be rapidly imaged at a high (diffraction-limited) spatial resolution where each pixel represents an area of 5.5 × 5.5 μm2 and contains a full infrared spectrum providing a chemical fingerprint which studies have shown contains the diagnostic potential to discriminate between different cell-types, and even the benign or malignant state of prostatic epithelial cells. We report a label-free (i.e. no chemical de-waxing, or staining) method of imaging large pieces of prostate tissue (typically 1 cm × 2 cm) in tens of minutes (at a rate of 0.704 × 0.704 mm2 every 14.5 s) yielding images containing millions of spectra. Due to refractive index matching between sample and surrounding paraffin, minimal signal processing is required to recover spectra with their natural profile as opposed to harsh baseline correction methods, paving the way for future quantitative analysis of biochemical signatures. The quality of the spectral information is demonstrated by building and testing an automated cell-type classifier based upon spectral features.
An investigation into the use of Raman optical tweezers to study urological cell lines is reported, with the ultimate aim of determining the presence of malignant CaP cells in urine and peripheral fluids. To this end, we trapped and analyzed live CaP cells (PC-3) and bladder cells (MGH-U1), because both prostate and bladder cells are likely to be present in urine. The laser excitation wavelength of 514.5 nm was used, with Raman light collected both in back- and forward-scattering geometric configurations. For the backscattering configuration the same laser was used for trapping and excitation, while for forward scattering a 1064 nm laser provided the trapping beam. Analysis of cell-diameter distributions for cells analyzed suggested normal distribution of cell sizes, indicating an unbiased cell-selection criterion. Principal components analysis afforded discrimination of MGH-U1 and PC-3 spectra collected in either configuration, demonstrating that it is possible to trap, analyze, and differentiate PC-3 from MGH-U1 cells using a 514.5 nm laser. By loading plot analysis, possible biomolecules responsible for discrimination in both configurations were determined. Finally, the effect of cell size on discrimination was investigated, with results indicating that separation is based predominantly on cell type rather than cell size.
One of the key reactions in the CVD growth of SnO2 on glass is that between SnCl4 and H2O. Exploiting the buried metal layer approach, we have used far-infrared RAIRS at the Daresbury synchrotron, to study the initial steps in this process on model glass surfaces, consisting of thin (approximately 500 - 1000 angstroms) SiO2 films and Na covered SiO2 films grown on a tungsten substrate.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.