The paper discusses the design, analysis, and testing of a rapidly cooled beryllium cryogenic mirror, which is the primary mirror in the four-element optical system for the Long Wavelength Infrared Advanced Technology Seeker. The mirror is shown to meet the requirement of five minutes for cooling to cryogenic operating temperature; it also maintains its optical figure and vacuum integrity and meets the nuclear specification. Results of a detailed thermal analysis on the mirror showed that, using nitrogen gas at 80 K as coolant, the front face of the mirror can be cooled from an initial temperature of 300 K to less than 90 K within five minutes. In a vacuum chamber, using liquid nitrogen as coolant, the mirror can be cooled to 80 K within 1.5 min. The mirror is well thermally insulated, so that it can be maintained at less than its operating temperature for a long time without active cooling.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.