Paper
21 April 1986 Telescope Constraints On Quasi-Optical Components For Submillimeter Radio Telescopes
G. A. Ediss, N. J. Keen, J. W. M. Baars
Author Affiliations +
Proceedings Volume 0598, Instrumentation for Submillimeter Spectroscopy; (1986) https://doi.org/10.1117/12.952329
Event: 1985 International Technical Symposium/Europe, 1985, Cannes, France
Abstract
The telescope effective focal length places major constraints upon the ability to design and build low loss quasi-optical components in the millimeter and submillimeter wavelength range. In this paper we discuss the principle problems involved in the design of such systems and report measurements of various quasi-optical components at 230 GHz and 460 GHz.
© (1986) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
G. A. Ediss, N. J. Keen, and J. W. M. Baars "Telescope Constraints On Quasi-Optical Components For Submillimeter Radio Telescopes", Proc. SPIE 0598, Instrumentation for Submillimeter Spectroscopy, (21 April 1986); https://doi.org/10.1117/12.952329
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Mirrors

Telescopes

Receivers

Radio telescopes

Near field

Optical instrument design

Absorption

RELATED CONTENT

Optical design of the 1.85 m mm submm telescope in...
Proceedings of SPIE (December 13 2020)
Heinrich Hertz Telescope
Proceedings of SPIE (July 31 1998)
Why not exposed extreme large telescopes?
Proceedings of SPIE (July 11 2006)

Back to Top