Paper
16 July 1986 Laser Shadow Method For Measuring The Diameter Of A Transparent Filament
G. C. Dubbeldam
Author Affiliations +
Proceedings Volume 0599, Optics in Engineering Measurement; (1986) https://doi.org/10.1117/12.952402
Event: 1985 International Technical Symposium/Europe, 1985, Cannes, France
Abstract
A new optical method for measuring the diameter of transparent filaments has been developed. It is based on determining the dimension of a sharp shadow image of the filament on a photo-detector. The influence of transmitted light is diminished by spatial filtering. The resolution is better than 1% for diameters down to 10 μm.
© (1986) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
G. C. Dubbeldam "Laser Shadow Method For Measuring The Diameter Of A Transparent Filament", Proc. SPIE 0599, Optics in Engineering Measurement, (16 July 1986); https://doi.org/10.1117/12.952402