Paper
6 February 2017 Novel ureteroscope illumination designs
Author Affiliations +
Abstract
Limitations of current ureteroscope illumination configurations include presence of shadows and hot spots in images, further degraded by stone debris during laser lithotripsy, which may result in a decrease in stone ablation efficiency, increase in surgical operation time, and potential collateral tissue trauma. Previous studies have reported accidental ureteral tissue perforation from Nitinol stone basket wires during Holmium laser lithotripsy, due in part to poor visibility. Although saline irrigation is routinely used during ureteroscopy to flush stone debris and improve visibility, sub-optimal illumination may still compound these problems. Current illumination geometries and sources are inadequate to produce necessary uniform illumination for optimal visibility and safety during ureteroscopy. By moving away from single and double point source geometry and towards a ring configuration, illumination becomes more uniform in both axes, reducing shadows and increasing depth discernibility. Uric acid and calcium oxalate based stones were chosen for illumination and reflection spectroscopy. Porcine ureters were used as soft tissue samples for comparison. The percent difference in reflection between ureter and stones was greater than 40% for the wavelength ranges of 470-540 nm, and 600-700 nm, making these spectral regions most suitable for high contrast illumination, possibly through narrow band imaging techniques via multiple laser sources and/or optical filters. These improved ureteroscope illumination designs and approaches may potentially reduce complications due to limited visibility during laser lithotripsy and hence increase patient safety.
© (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Christopher R. Wilson, Joseph A. Peller, Susan R. Trammell, Pierce B. Irby M.D., and Nathaniel M. Fried "Novel ureteroscope illumination designs", Proc. SPIE 10038, Therapeutics and Diagnostics in Urology: Lasers, Robotics, Minimally Invasive, and Advanced Biomedical Devices, 100380P (6 February 2017); https://doi.org/10.1117/12.2247598
Lens.org Logo
CITATIONS
Cited by 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Reflectivity

Tissues

Reflectance spectroscopy

Laser lithotripsy

Light sources

Light sources and illumination

Absorption

Back to Top