Paper
3 March 2017 In vivo measurement of the tissue oxygenation by time-resolved luminescence spectroscopy of protoporphyrin IX: strategies to minimize artefacts associated with photoproducts
Emmanuel Gerelli, Veronika Huntosova, Denis Horvath, Georges Wagnières
Author Affiliations +
Abstract
The determination of the oxygen partial pressure (pO2) in real time in living biological tissues is of high interest for numerous therapeutics, including photodynamic therapy (PDT) and radiotherapy. The minimally invasive and real-time measurement of the pO2 also enables to obtain interesting fundamental information regarding the metabolic activities in cells and tissues. The development of time-resolved luminescence measurement (TRLM) methods combined with the availability of new oxygen-sensitive molecular probes is at the origin of the significant progress that have been achieved during these past decades to measure the pO2 in living organisms. These probes include porphyrins, such as aminolevulinic acid-induced protoporphyrin IX (PPIX), which is an approved photosensitizer. Using the photosensitizer to probe the pO2 is of high interest in PDT since the level of oxygen is measured at the precise location where the phototoxic mechanisms take place. However, PPIX has drawbacks to measure the pO2 by TRLM, including its significant photobleaching. Since the PPIX excitation during pO2 measurements leads to the generation of its photoproducts, we studied the impact of their luminescence on the measurement of the PPIX triplet state lifetime in solution and in vivo on the Chick’s Chorioallantoic Membrane (CAM) model. We performed this study under various oxygen conditions. Our results indicate that perturbations induced by these photoproducts can be avoided if the PPIX luminescence is detected between 620 and 640 nm, or if PPIX is excited at 405 nm with light doses < 1 J/cm2.
© (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Emmanuel Gerelli, Veronika Huntosova, Denis Horvath, and Georges Wagnières "In vivo measurement of the tissue oxygenation by time-resolved luminescence spectroscopy of protoporphyrin IX: strategies to minimize artefacts associated with photoproducts", Proc. SPIE 10060, Optical Biopsy XV: Toward Real-Time Spectroscopic Imaging and Diagnosis, 1006016 (3 March 2017); https://doi.org/10.1117/12.2256669
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Luminescence

Oxygen

Content addressable memory

Photodynamic therapy

Tissues

Spectroscopy

Time resolved spectroscopy

Back to Top