Paper
26 June 2017 Tolerance on sphere radius for the calibration of the transfer function of coherence scanning interferometry
Author Affiliations +
Abstract
Although coherence scanning interferometry (CSI) commonly achieves a sub-nanometre noise level in surface topography measurement, the absolute accuracy is difficult to determine when measuring a surface that contains varying local slope angles and curvatures. Recent research has shown that it is possible to use a single sphere with a radius much greater than the source wavelength to calibrate the three-dimensional transfer function of a CSI system. A major requirement is the accurate knowledge of the sphere radius, but the three-dimensional measurement of a sphere with nanometre level uncertainty is a highly challenging metrology problem, and is not currently feasible. Perfect spheres do not exist and every measurement has uncertainty. Without having a quantitative understanding of the tolerance of the sphere radius, the calibration method cannot be used confidently for calibration of the transfer function of a CSI system that may be used in research laboratories or industry. In this paper, the effects of the tolerance of the radius of the calibration sphere on surface topography measurements are quantitatively analysed through a computational approach. CSI measurements of spherical, sinusoidal and rough surfaces are investigated in the presence of various degrees of radius error. A lookup table that relates the surface height error as a function of the radius error and surface slope angle is provided. The users may estimate the required tolerances of the sphere radius for their specific surface measurements if this calibration approach is used. The output of this paper provides a feasibility analysis for this calibration method for further development and applications.
© (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Rong Su, Jeremy M. Coupland, Yuhang Wang, and Richard K. Leach "Tolerance on sphere radius for the calibration of the transfer function of coherence scanning interferometry", Proc. SPIE 10329, Optical Measurement Systems for Industrial Inspection X, 103290L (26 June 2017); https://doi.org/10.1117/12.2272041
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Tolerancing

Interferometry

Analytical research

Metrology

Spherical lenses

3D modeling

RELATED CONTENT

Domestic round-robin tests in Japan for about 40 years
Proceedings of SPIE (September 30 1998)
High-precision testing of optical components
Proceedings of SPIE (September 21 1998)

Back to Top