|
I.INTRODUCTIONLight scattering in optical coatings has been the focus of numerous studies for decades. Indeed in a way similar to absorption, scattering has driven the performances of the most complex interferential filters. The origins of scattering can be found in roughness at the stack interfaces and bulk inhomogeneities in the film bulks. It was well established that all these defects include the replication of the substrate roughness at each interface, as well pits due to the deposition process and localized defects resulting from dusts. Moreover, a residual roughness can be introduced in relationship with the thin film material grain size. Most difficulties have been considerably reduced in the 2000’s, and are mainly due to the improvement of cleaning and polishing processes, together with deposition technologies and monitoring processes. However these new technologies today allow to deposit a much higher number of layers and a new complexity has increased in consequence. Within this framework scattering phenomena must again be investigated with more detail, including spectral, angular and polar variations resulting from each illuminated pixel on the surface sample. Due to new computer performances, light scattering can be easily calculated for complex filters and take simultaneously account of most parameters: surface roughness, bulk inhomogeneity, cross-correlation coefficients, errors in design, wavelength and scattering angles (normal and polar), polarization… All these variations have become necessary to predict a balance in optical multiplexers and related systems, mainly for space applications. Some examples are given in the figures further, with a special focus on polar and spectral variations, that emphasize the complexity of the process. In order to face such huge collection of data, is has become more and more necessary to have at disposal a facility able to measure the same information. For this reason new developments were performed in Marseille these last years, that we will first recall. Then we show how to extend these facilities and try to reach a multimodal scatterometer. II.LIGHT SCATTERING AND OPTICAL MULTILAYERS: NUMERICAL TOOLSBased on first order vector theory, the electromagnetic field scattered by a multilayer can be calculated as a function of the stack formula, the illumination conditions (optical term C), the microstructure of the component (γ is representative of the interfaces roughness or the bulk inhomogeneities in the layers). The expression of the intensity of the light scattered by an optical multilayer is given eq(1) as a function of the scattering angles (θ,ϕ) defined Figure 1, the illumination wavelength (λ) and angle (i). In eq (1), p and q are indexing the layer #, hp is the profile of interface #p, ĥp its Fourier transform, δp its rms roughness and γp its roughness spectrum or permittivity spectrum. With And As an illustration, the BRDF (Bidirectionnal Reflectance Distribution Pattern) calculated for a complex optical filter (91 layers self blocking filter) as a function of the normal scattering angle θ, in the incidence plane ϕ = 0° and λ = 740 nm is given Figure 2. For the characterization of optical coatings, the illumination wavelength has to be taken into account. As an example, we plotted in Figure 3 the spectral and angular variations of the intensity of the light scattered by a single-cavity Fabry Perot filter. As usual, the scattering rings appear in the spectral band-pass. Progress made in the last few years by technical deposition processes now allows to produce optical filters with much higher complexity (Figure 4), which increases the difficulty when analyzing such filters. Moreover, as shown on Figure 5, the 3D spatial repartition of the angular resolved scattering pattern (ARS) under normal incidence follows a polar symmetry. Fewer results can be found for polar dependence at oblique illumination, results that are given in figure 6. As illustrated on these numerical results, numerous parameters have to be taken into account for a comprehensive light scattering characterization of optical components. But, in term of experiment, they cannot be considered with the same accuracy at the same time, so it has been necessary to involve new facilities which now constitute a metrological platform dedicated to light scattering characterization. IIIMULTI-WAVELENGTH 3D ARS SET-UPA multi-wavelength 3D ARS set-up (Figure 7) located in a clean room allows the measurement of 3D scattering patterns at a wavelength which may be chosen between laser rays within [458 nm; 10.6 μm]. The signature of the instrument in the incident plane for an illumination wavelength of 633 nm is given Figure 8. Thanks to a high sensitivity CCD-array, measurements performed with extremely high angular resolution allow the recording of speckle intensity cartographies as shown on Figure 9-right. Statistical repartition of the speckle intensity extracted from only one intensity measurement allows discriminating the scattering origins as shown on Figure 9-left. To go further, the polarisation state of the incident light can be modulated and the recording of the polarimetric phase shift of the light scattered by the illuminated component allows a complementary discrimination of the scattering origin as illustrated on Figure 10. Moreover, polarisation state of the scattered wave can be measured with a resolution better than the speckle size. Under polarized illumination, the repartition of these polarization states can be related to the roughness and the mean slope of the illuminated surface. Figure 11 illustrates the numerical modelisation of the repartition of the polarization states of light scattered by different surfaces with rms roughnesses hrms. IVCCD-ARS SET UP: TO EXTRACT THE INFLUENCE OF LOCALIZED DEFECTSOne of the main problematic in light scattering characterization is the influence of defects localised on the sample surface. As illustrated Figure 12, only a few defects located on the illuminated area can modify significantly the shape and the level of the ARS pattern generated by the illuminated surface. As a consequence, if a surface whose intrinsic roughness is 0.87 nm is considered, the presence of only 10 localised defects on the sample will lead to the recording of a 3.93 nm by light scattering characterization. The previous example showed us that the influence of localized defects cannot be neglected in light scattering characterization, so a dedicated set up was involved. The CCD-ARS set up is a goniometric light scattering instrument with high-resolution imaging. A schematic view of the set-up is given Figure 13 and the instrument signature can be seen Figure 14. The illumination system is rotating around the sample surface and the area illuminated on the component is a 15.9x15.9 mm2 square. For each lighting angle, the illuminated area is imaged with a very high-sensitivity CCD-array and a telecentric objective. The studied area is divided in more than 700 000 elementary 26μmx26μm surfaces and the BRDF pattern of each of them is recorded at the same time. You can see Figure 15 an example of measurement performed on a contaminated Germanium wafer. Three BRDF patterns are plotted. First one (in red) is for an elementary surface free of defect, so, representative of the intrinsic roughness. Second one (in blue) is for an elementary surface with a defect (blue), so the corresponding angular pattern presents some oscillations which are representative of the defect. And third one (green) is representative of the scattering level of a 2x2mm2 square without localization of the defects and as a consequence is representative of the BRDF pattern which would have been recorded with standard ARS set-up. This example is illustrating the fact that compared to a classical BRDF measurement (green curve), the scattering pattern measured with the CCDARS set up is representative of the intrinsic roughness of the surface (red curve) or obviously show the presence of a defect (blue curve). To extract from the spatially resolved BRDF measurement an accurate localisation of the defects on the surface, dedicated algorithms were involved. An example of application to the measurement shown Figure 15 is given Figure 16 where we can see the cartography of the local roughness measured on the sample with a spatially resolved ARS pattern measurement and after extraction of the pixels for which the signal recorded was affected by the presence of a defect. Thanks to the huge number of resulting data, the statistical repartition of local roughness can be studied. An example of application is given Figure 17. At last, as shown on Figure 13, we can add a polarization state generator and analyzer to the CCD-ARS set up. Such e new configuration allows us to record for each lighting angle, the Mueller matrix of the sample surface. The study of the polarimetric state of the light scattered by the component can give us complementary information on the nature of the defects. For example, we can see Figure 18, in the red circles the identification of 2 localized defects which have two different polarimetric behaviors. And this shows us that these two defects are not from the same material. So the use of the spatially resolved Mueller imaging allows the discrimination between different kind of defects. To go further and to reach a comprehensive light scattering characterization, as shown in part II, it is necessary to take into account the spectral effects. For this reason, we developed a spectrally resolved ARS set-up. VSPECTRALLY RESOLVED ARS SET-UPLast facility involved at the lab is a ARS set-up which allows to choose the illumination wavelength. The system uses a super continuum laser as a source. Its emission spectrum is given Figure 19. As shown Figure 20, a spectral splitter and a double monochromator are added to the super-continuum laser in order to get an illumination source with a 0.5 nm spectral bandwidth and a tunable central wavelength on the range [480nm-2000 nm]. Moreover the use of remoted density allows an automatic tuning of the incident power on the component. The set up is detailed Figure 20. The sample is illuminated using an achromatic collimator and the light scattered by the component is collected by the symmetric achromatic collimator. Then, the collected light is sent to the sensor through an optical fiber and a secondary imaging system which will image the interface of the collection fiber on a high sensitivity CCD array. An important thing to notice here is that the use of a high power source and a high sensitivity CCD-array allow the recording of low level intensities, so the recording of scattering patterns. And, on the other hand, the presence of remoted optical densities allows the measurement of high level intensities, so the recording of specular and direct beams is made possible. For these reasons, measurements can be performed with more than 12 decades of dynamic. The calibration of the set up is performed with the measurement of a perfect diffuser (following a lambertian law), the resulting recorded pattern and the instrument signature are given Figure 21 for a 600 nm illumination wavelength. An example of application is given Figure 22 where we can see the measurement performed on a complex optical filter. The ARS patterns were recorded for three different illumination wavelengths: λ = 641 nm, λ = 740 nm, λ = 840 nm and for the two first wavelengths, the presence of scattering rings can be noticed. CONCLUSIONThe increasing complexity of thin film coatings generates new problematics in light scattering phenomena. To face these challenges, new facilities and modelization tools were involved at Institut Fresnel in the last few years and were presented in this paper. Numerical results illustrate the fact that numerous parameters have to be taken into account for a comprehensive light scattering characterization of optical components. But, in term of experiment, they cannot be considered with the same accuracy at the same time, so it has been necessary to involve new facilities which now constitute a metrological platform dedicated to light scattering characterization. At last, this platform was designed for the characterization of optical component, so metrological specifications are drastic but it can also be extended to other fields of application such as biological tissues, microcavities and lighting… REFERENCESC. Amra,
“Light scattering from multilayer optics. II. Application to experiment,”
J. Opt. Soc. Am. A, 11
(1), 211
(1994). Google Scholar
C. Amra,
“Light scattering from multilayer optics. I. Tools of investigation,”
J. Opt. Soc. Am. A, 11
(1), 197
(1994). Google Scholar
C. Amra, C. Grezes-Besset, and L. Bruel,
“Comparison of surface and bulk scattering in optical multilayers,”
Appl. Opt., 32 5492
(1993). Google Scholar
J. M. Bennett and L. Mattsson, Introduction to Surface Roughness and Scattering, 2OSA, Washington, DC,,1999). Google Scholar
A. Duparre, B. J. Ferre, S. Gliech, G. Notni, J. Steinert, and J. M. Bennett,
“Surface characterization techniques for determining the root-mean-square roughness and power spectral densities of optical components,”
Applied Optics,
(2002). Google Scholar
P. Roche and E. Pelletier,
“Characterizations of optical surfaces by measurement of scattering distribution,”
Appl. Opt., 23
(20), 3561
–3566
(1984). Google Scholar
J. C. Stover,
“Optical Scattering: Measurement and Analysis,”
in SPIE,
(1995). Google Scholar
J. Sorrentini, M. Zerrad, and C. Amra,
“Statistical signatures of random media and their correlation to polarization properties,”
Opt. Lett., 34 2429
–2431
(2009). Google Scholar
O. Gilbert, C. Deumié, and C. Amra,
“Angle-resolved ellipsometry of scattering patterns from arbitrary surfaces and bulks,”
Opt. Express, 13 2403
–2418
(2005). Google Scholar
S. Maure, G. Albrand, and C. Amra,
“Low-level scattering and localized defects,”
Appl. Opt., 35
(28), 5573
–5582
(1996). Google Scholar
M. Zerrad, C. Deumié, M. Lequime, and C. Amra,
“An alternative scattering method to characterize surface roughness from transparent substrates,”
Opt. Express, 15
(15), 9222
–9231
(2007). Google Scholar
M. Lequime, M. Zerrad, C. Deumie, C. Amra,
“A goniometric light scattering instrument with high-resolution imaging,”
Optics Communications, 282 1265
–1273
(2009). Google Scholar
M. Zerrad, M. Lequime, C. Deumie, and C. Amra,
“Characterization of Optical Coatings with a CCD Angular and Spatial Resolved Scatterometer,”
presented at the Optical Interference Coatings,
(2007). Google Scholar
M. Zerrad, M. Lequime, C. Deumie, and C. Amra,
“Development of a goniometric light scatter instrument with sample imaging ability,”
in presented at the SPIE Europe Optical Systems Design (Invited Paper),
(2008). Google Scholar
M. Zerrad, M. Lequime,
“CCD-ARS set-up: a comprehensive and fast high-sensitivity characterisation tool for optical components,”
in SPIE Photonics Europe,
(2010). Google Scholar
M. Zerrad, M. Lequime, C. Amra,
“Multimodal high-sensitivity ARS set-up” Multimodal high-sensitivity ARS set-up,”
in SPIE Europe Optical Systems Design,
(2011). Google Scholar
M. Zerrad and M. Lequime,
“Instantaneous spatially resolved acquisition of polarimetric and angular scattering properties in optical coatings,”
Appl. Opt., 50 C217
–C221
(2011). Google Scholar
|