Presentation
18 September 2018 Recommendations and lessons learned from testing a prototype gamma-ray imaging diagnostic system for NIF (Conference Presentation)
Author Affiliations +
Abstract
The National Ignition Facility at Lawrence Livermore National Laboratory is in need of a gamma-ray imaging diagnostic system to image imploding capsules for inertial confinement fusion experiments. A prototype system was designed and constructed to image 4.44 MeV gammas resulting from 12C(n,n’ γ)12C interactions with the plastic ablator. Testing of the system was undertaken at the OMEGA Laser at the University of Rochester using hard x-rays from an imploding capsule and at the High Intensity Gamma Source at Duke University using a 4.47 MeV gamma beam. The results of these tests produced a number of lessons and recommendations presented here.
Conference Presentation
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Daniel A. Lemieux, Gary P. Grim, and H. Bradford Barber "Recommendations and lessons learned from testing a prototype gamma-ray imaging diagnostic system for NIF (Conference Presentation)", Proc. SPIE 10763, Radiation Detectors in Medicine, Industry, and National Security XIX, 107630R (18 September 2018); https://doi.org/10.1117/12.2326513