15 February 2021 A novel approach to calculating dual energy in the angiography suite
Author Affiliations +
Abstract
Purpose: Medical management after endovascular treatment (EVT) for acute ischemic stroke involves blood pressure management and antithrombotic medications which are strongly influenced by hemorrhagic complications of the procedure. In this study our aim is to modify a commercially available c-arm angiographic system to assess feasibility of distinguishing between blood and iodinated contrast using dual-energy CT technology. Methods: An angiographic C-arm system was manipulated with the addition of a flat sheet of tin (Sn) filtration with corresponding calibration. Two flat-panel cone-beam CT (FP-CBCT) were acquired at 70 kV and 125Sn kV. A multienergy CT phantom with iodine inserts at various concentrations ranging from 0.2 to 15 mg/cc was used to characterize the behavior (i.e. dual-energy ratios DER) of the materials as a function of the kVp pair. DER values were needed to adjust an existing material decomposition software. The accuracy of iodine quantification was assessed with inserts including solid water, iodine, blood and mixed iodine and blood; all with concentrations ranges relevant for stroke imaging. Results: Imaging indicated the ability to differentiate between blood and iodine for the use with FP-CBCT. Pure blood and iodine inserts fell within the 95% confidence interval for precision of contrast concentration measured. For iodine inserts, the error from expected measurement was 7.5% or under for inserts with concentrations above 2 mg/cc. Inserts containing a combination of blood and iodine were consistently reading 1 mg/ml or less deviations relative to the value of the material specified by the manufacturer, which represented a 25-35% error difference from the expected value. Conclusion: These results establish the reproducibility of the phantom values for dual energy calculations and suggest that this technology may be clinically useful after EVT for stroke. Improvements in the accuracy of the iodine/blood combination under dual energy evaluation is needed for other applications outside of the use for differentiating between hemorrhage and contrast staining.
Conference Presentation
© (2021) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Julie M. DiNitto, Juan Carlo Ramirez-Giraldo, and Michael Froehler "A novel approach to calculating dual energy in the angiography suite", Proc. SPIE 11595, Medical Imaging 2021: Physics of Medical Imaging, 115950V (15 February 2021); https://doi.org/10.1117/12.2581747
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Iodine

Blood

Dual energy imaging

Angiography

Tin

Manufacturing

Blood pressure

Back to Top