1.INTRODUCTIONThe predominant materials in aerospace manufacturing used to be aluminum, steel, and titanium, which accounted for up to 70% of the typical aircraft. However, with the growing demand for weight reduction, better fuel economy, and lower operation costs, metals are losing ground in the airframe composition to composite materials, which are lighter and resistant to corrosion and fatigue. Additionally, the sector is making a transition to a more electric aircraft, increasing the thermal vulnerability of the structure because the number of potential heat and fire sources increases: new equipment that may cause overheating and accidentally cause a fire is being required (batteries, EHA and EMA actuators, ice protection, e-braking and taxiing) while traditional heat sources and hazards (bleeding tubes, nozzle exhausts, engine and APU, fuel system) still remain. This trend is a potential challenge for the expansion of the use of composite materials, since the application of fire or high temperatures may induce serious damage in them. Degradation includes polymeric matrix decomposition and melting, growth of voids, the formation of bubbles with gases inside and other structural damages that may cause the loss of mechanical resistance and finally, under loading or after enough time, mechanical failure.1 One of the aims of the Airframe Integrated Technology Demonstrator of the Clean Sky Joint Undertaking of the European Commission and the European aeronautics industry, funded by the Horizon 2020 initiative, is to achieve lighter and more cost-effective structures by increasing the structural contribution of more efficient composites. Under this framework, the research project HITCOMP2 aims to characterize the behavior, under fire and thermal affection, of new high-performance thermoplastic composites based on Poliaryletherketone (PAEK) family resins. These promising materials show some advantages over the current widely used thermoset composites based on epoxy resins, including good chemical resistance to acids, alkali, and organic solvents;3 elevated temperatures for glass transition (Tg ≈ 143°C) and fusion (Tm ≈ 343 – 380°C);1,4 low heat release rate and small smoke emission when burned.1 In addition, they retain useful mechanical properties well above their Tg, with a continuous service temperature (CST) of ≈ 250°C.3 These properties make them very well suited for high-temperature applications, specifically in fire-prone or thermally demanding areas of the structure such as nacelle compartments, movable surfaces affected by engine nacelle exhaust, or any other area of the structure affected by hot air exhaust impact. On the other hand, the detailed properties of thermoplastic composites are not yet well known, and for that reason a large number of tests should be done to complete their thermomechanical characterization. The most popular methods for composite characterization under fire are those based on calorimetric cones, since they allow controlling all the boundary conditions, but the more informative and realistic are fire tests, in which a sample of the material is exposed to a calibrated flame. However, these tests are destructive, expensive, and cumbersome to perform, and so it would be highly desirable to minimize their number, by maximizing the information obtained from each of them. In this work, we employ an innovative measurement setup, previously developed,5 for the fire test. Using two co-registered IR cameras, it provides accurate, non-intrusive measurements of the actual temperature distribution at both faces of the sample, as a function of time, in the real test conditions. This information, together with values of thermal parameters obtained with an adapted flash method,5,6 is used by a thermo-mechanical finite-element model (FEM) to simulate the behavior of the material. The comparison of simulation and experimental measurements allows for the adjustment and validation of the model. The final aim is to reduce the cost in money and time of thermal characterization of thermoplastics, by being able to “virtualize” at least some of the tests and to predict their behavior and resistance when submitted to fire or high-temperature events. In the long run, this should make it possible to forecast the time to failure for a determined specimen of a thermoplastic composite material submitted to fire, with any number of layers, thickness, specific attachment, airflow rate in the cold face, mechanical load, etc. In this paper, Section 2 reviews the basic principles of thermal characterization by a modified flash method that takes into account thermal losses and shows the results obtained in the samples studied as well as their validation by means of step-heating tests. It is found that behavior at temperatures above ~ 150°C cannot be well reproduced with the room temperature parameters, and thus the effect of exposure to high temperatures on the thermal parameters is studied in Section 3, by heating samples in a furnace. Characterization at room temperature finds no changes for furnace heating up to ~ 450°C, which is interpreted as evidence of reversibility of the temperature-induced changes below that temperature in thermoplastic materials, as opposed to the irreversible behavior of thermosettings. The study of samples under real fire conditions becomes therefore essential, and is carried out in Section 4, which describes the experimental measurements and results provided by the two-cameras measurement setup. These results have been reproduced by a FEM model in Section 5. The model proposes a dependence of effective thermal parameters with temperature, which is validated by the good fitting of the experimental results. Finally, 6 summarizes the paper and draws the conclusions of this work. 2.THERMAL CHARACTERIZATION OF THERMOPLASTIC MATERIALS AT ROOM TEMPERATURE2.1Flash testThe thermal parameters of the thermoplastic material at room temperature have been obtained by application of the flash test. This well-known technique of thermal characterization is based on the analysis of the time evolution of temperature at the rear face of a flat sample when it is heated by a very short and intense pulse of radiation at the front face. It was first developed by Parker et al7 to measure diffusivity α [m2/s] for specimens in which heat losses are negligible (Biot number Bi ≈ 0). Diffusivity and Biot number are defined as where κ [W/m·K] is the thermal conductivity, ρ [kg/m3] the density, cp [J/kg·K] the specific heat, h [W/m2·K] the heat transfer coefficient and L [m] the sample thickness. Degiovanni8 and other authors extended the flash method for the general case of non-negligible heat losses by proving that, if a normalized temperature increase (T*) and a dimensionless time (t*) are defined by then for each Biot number there is a unique T*(t*) function with a well-known analytical expression. Therefore, Bi and α can be obtained by fitting the T* vs t* experimental profile with the T*(t*) function calculated numerically.6 Figure 1 shows the time evolution of T* vs t* in two flash experiments for specimens of two different thicknesses (1.5 and 4.5 mm), together with the fitting analytical function. Once Bi and α have been determined, thermal conductivity can be obtained from equation (1) if the volumetric heat capacity ρ·cp is known. If there were no heat losses and the heat density Q [J/m2] supplied by the lamp were known, ρ·cp could be solved from where Tlim is the uniform temperature of the sample when t → ∞. In a real sample, heat losses imply that Tlim is not reached, but its value can be calculated from the maximum temperature at the rear of the sample Tmax and the Biot number.5,6 Thus, using a lamp with known Q makes it possible to find ρ·cp and therefore κ. This procedure has been applied to five specimens of thermoplastic composite, three of them with L = 1.5 mm and two with L = 4.5 mm, with the same nominal composition. There were no significant differences between the parameters of the samples of different thicknesses. The (mean ± standard deviation) measured values were α = (5.6 ± 0.1)·10–7 m2/s, ρ·cp = (1.36 ± 0.05)·106 J/m3K and κ = 0.77 ± 0.04 W/m·K. 2.2Validation of parameters: Step testIn order to validate the thermal parameters previously obtained, a different procedure is used: the step test. A ceramic radiant heater is applied close to the specimen front face (Figure 2, left) and keeps heating it until a steady state is reached. To obtain a sharp start of the heating (square-like pulse), an insulating screen is placed between the heater and specimen and abruptly removed when the heater is stabilized. Temperature maps of both front and back face (Figure 2, right) are recorded and co-registered in space and time. The time evolution of the measured temperature in the rear face is compared to the result of a finite element method (FEM) simulation, that uses as input the thermal parameters obtained from the flash test and the measured temperature the front face as a function of time. Figure 3 shows experimental and simulated profiles from the first step test performed, on the sample with thickness 1.5 mm. In this experiment, the agreement between the simulated and experimental profiles gets worse as the temperature of the front face increases. This suggests that the lack of agreement can be due to the variation of thermal parameters with temperature. A new step test was carried out with a different heat source so that temperatures of the sample were kept relatively low. Figure 4 shows that in this case the relative error in temperature between the experimental and simulated profiles is kept very small, being always less than 1% in K. These results validate the thermal parameters obtained for moderate temperatures (< 150°C). Therefore a first critical temperature Tc1 is established tentatively at ≈ 150°C, a value which is in the range of the glass transition temperature Tg. Assuming a degradation of the thermal parameters above Tc1 makes possible to achieve a much better agreement with the experimental results, as will be explained in Section 5. 3.FURNACE TESTAfter the flash tests of virgin material just described, the effect of temperature on the samples was tested by uniform heating the specimens in a furnace. When thermal equilibrium was reached at a prescribed temperature, the samples were allowed to cool down at room temperature and the thermal parameters were obtained using the flash technique. A maximum furnace temperature of 500°C was reached. Figure 5 shows the results for a y κ in a sample for the different furnace temperatures used. Thermal properties measured at room temperature show no appreciable degradation even in samples heated up to ~ 450°C in the furnace. This result was not expected on the basis of our previous experience with fire tests of thermosetting materials, where two critical temperatures appear. First, the material begins to change its thermal properties and to drop its mechanical strength and stiffness (leading to failure if large loads are applied) between ~ 280°C and ~ 300°C depending on the specific material. This critical temperature (Tc1) that corresponds approximately to the glass transition temperature, Tg, of thermosets. Then, at around 350-360°C or even higher temperatures (Tc2), the polymeric matrix becomes fully degraded into volatiles and char. Thereafter, only the fibers survive, and the material can be assimilated to a loose fabric. For thermoplastic materials, the behavior was expected to be similar below Tg but different above, with an additional drop of the Young modulus9 at temperatures above Tc1, but requiring higher temperatures, near 500° C to achieve full degradation with chemical decomposition.10 The fact that no critical temperatures are found in these experiments below that temperature range may be explained if thermal changes do take place during heating above 150°C, but they are reversible and thus the material, when cooled to room temperature, does not show appreciable changes. This reversible behavior is quite different from that of thermosetting composites, which, if heated above Tc1, do not change very much their thermal properties when cooled down. Irreversible changes, however, have been observed in the thermoplastic material for Tfurnace > 450° C: a drastic degradation appears, with a sevenfold decrease in both alpha and kappa (the change in volumetric heat capacity is very small, however). The reversibility of thermal properties below ~ 450°C in the present case means that their effective value in the fire tests for that range of temperatures cannot be provided by our flash technique setup, since it cannot be used for the material while at the furnace. On the other hand, it must be noted that there are important differences between uniform heating in a furnace and heating by a flame, since the latter is much faster and very inhomogeneous spatially. This creates large temperature gradients that, in turn, bring about internal stresses that are a source of degradation; thus, in a fire resistance test this process should begin at temperatures lower than in the case of furnace heating. This means in practice that our objective should be to obtain effective parameters that provide a good simulation of the fire test, rather than aiming at properties of the material measured for quasiestatic, homogeneous heating, that may be not useful for a sample whose temperature is extremely inhomogeneous and changes very fast. 4.THERMAL CHARACTERIZATION OF THERMOPLASTICS UNDER FIREThe measurements reported in the previous sections have established the reversibility of the thermal properties of the thermoplastic material for homogeneous and slow heating below ~ 450°C, and have not found critical temperatures as those exhibited by thermosetting materials. However, this kind of process is quite different from the fast and inhomogeneous heating experimented by a material exposed to a fire, and therefore it becomes necessary to perform a test with a real fire and analyze the behavior of the material in situ. Since the evolution of the slope of the temperature versus time profiles provides information on critical temperatures,5,11 this test could provide realistic values for Tc1, Tc2 in thermoplastics. The test could give also valuable information to calculate thermal parameters at temperature ranges above 150°C, where step heating experiments were not well fitted by the room temperature values (see Figure 3). The fire test was carried out at the AIRBUS facilities in Getafe (Spain), according to the ISO 2685:1998 standard. The dimensions of the sample were 600 × 400 × 4.5 mm. Two infrared cameras imaged both sides of the sample during the fire test, providing surface temperature maps spatially co-registered.5 The front face camera was a FLIR A325 fitted with a band-pass interference filter (wavelength center 9565 nm, full width at half maximum 95 nm) to minimize the effect of flame emitted radiation, and was calibrated for temperatures up to 1000° C. The rear face camera was a Sensia Caroline with a spectral range from 7 to 12 μm. Figure 6 shows a scheme and a photograph of the setup. Figure 7 shows the temperature maps of the front (left) and rear (right) faces at two times during the fire resistance test: while the temperature is rising, at t = 22 s (top) and when a nearly steady state has been reached, at t = 80 s (bottom). The flame impacted on the left side of the sample, as can be seen in the front-face images. A reflection of the burner can be seen as well on the right side, but its effect on the mapped temperature values is very small. A striking fact is the large temperature difference between the front and rear faces. At the steady state, a thermal drop of about 540°C is reached for a thickness of 4.5 mm, i.e., the temperature gradient across the plane is ~ 120°/mm. There is also an in-plane gradient, that can be as large as ~ 2.5°/mm, which explains the progressive uniformization of temperatures at the rear face, due to in-plane heat conduction in the sample. The relative low temperature of the rear face explains that, contrary to the usual result in thermoset composites, no bubble-like degraded zones were found. 4.1Thermal profiles: front faceMore detailed information can be obtained from the time profiles of temperature during the experiment. The temperature vs time evolution of several points on the front side of the sample (whose positions are shown in Figure 8) is plotted in Figure 9. After the start of fire application, the temperature increases more or less uniformly, although transitory maxima of temperature are observed at different times (≈40, 60, 100 s). Our working hypothesis is they are caused by the appearance of volatiles produced by evaporation during the melting of the resin. These volatile pockets grow and are expelled as the material degrades, repeating the process from time to time, producing bubbles where the most superficial layers of the sample lose adherence with those below, and their temperature increases due to the reduced capacity to evacuate heat to the rear side. However, this effect does not significantly affect either the thermal characterization or the validation of the thermal model. There is a more relevant effect that can be seen in all the profiles from the hottest points (1, 2, 3, 8, and 9): a sudden increase in temperature when T exceeds ~ 300°. A more detailed study using the time derivative of T shows that there are in fact two abrupt changes in slope; one around 300°C (a point of inflection in the T(t) graph) and another around 370°C, as can be seen in Figure 10 (the estimated error in these values is around 3% in K). These are the points of extreme slope (letting aside the maxima at the sudden turning on and off of the fire, and the long-term minimum when reaching the stationary temperature) and thus they mark significant features of the behavior of the material. In particular, they are probably related to the melting point, that, as mentioned in the Introduction, is situated between ≈ 343 – 380°C for the PAEK family resins. 4.2Thermal profiles: rear faceThe same points marked in Figure 8 have also been studied on the cold side. The evolution of temperature is more regular, without the transitory maxima found in the front face, as expected since at the lower temperatures of the rear face resin does not melt and no bubbles with volatile emission appear. The profiles evolve uniformly up to a nearly stationary regime, although a decrease in temperature can also be seen from 100 s onwards. A probable explanation is the already mentioned loss of adherence between layers near the front face, due to emission of volatile gases at high temperatures, that increases overall thermal isolation between both faces of the sample. 5.CHARACTERIZATION AND SIMULATIONThe study of temperature profiles in the previous section found a maximum in the slope of T vs t at a temperature of around 370°, that corresponds approximately with the expected melting temperature. Although it is expected that the complete chemical degradation of the material is not reached until ≈ 450 – 500°, as explained in Section ??, there are no additional marked features in the slope of T vs t. To keep the model simple, it will be assumed that, regarding the effective thermal parameters in the fire test, the material reaches a maximum degradation at Tc2 = 370°. Besides, the fact that step heating experiments have shown that room temperature parameters do not fit the thermal behavior above 150°C, suggests, as explained in Section 2.2, that some degree of thermal degradation begins above that temperature, although it does not appear in the furnace heating experiments because it is reversible. Therefore, we will propose the initial hypothesis, yet to be validated, that effective thermal properties in the fire test begin to change at Tc1 ≈ 150° C and complete their degradation at Tc2 ≈ 370°C. Within this interval lies the inflection point at Ti ≈ 300°C, that may mark a with a probable change in their dependence on temperature. 5.1Finite element modelWith these constraints, and assuming for simplicity linear dependence on temperature, several values of the thermal parameters have been proposed and used to fit the experimental results of the fire test with a finite element model (FEM). The model uses the proposed thermal parameters as input, as well as the experimental distribution of temperatures at the front face as a function of time, and produces as output the predicted distribution of temperatures in all points of the sample, in particular, at the rear face, also as a function of time. Values at room temperature and up to Tc2 = 150°C are those obtained by the flash method as explained in section 2.1, whereas those at Ti = 300°C and Tc2 = 370°C have been varied systematically to find the best agreement between prediction and experiment. Values that provided the best agreement are shown in Table 1, with their dependence on temperature plotted in Figure 12. Table 1:Effective thermal parameters of thermoplastic at different temperatures.
An example of simulation of the fire test using these data is shown in Figure 13, for a point at the hottest region of the sample. The agreement of the simulation results is quite good, with an error below 3% in K. However, it should be borne in mind that the present simulation cannot reproduce some effects, like those derived from local delaminations, internal bubbles of volatiles, etc, that are probably responsible for the transitory maxima found in Figure 9. This explains discrepancies between calculation and experimental profile in the first stage of the fire test (up to, approximately, t=60 s). In a similar way, the cooling down of the experimental profile in the rear face after 100 s is probably caused the loss of adherence between layers due to the emission of volatiles (see Section 4.2), another effect that cannot be reproduced by the simulation, which explains the discrepancy at the last stage of the fire test. The FEM model makes it possible also to simulate the degradation of the specimen through its thickness. Figure 14 shows the inhomogeneous degradation of specimen 80 s after fire application due to the high gradient of temperatures across the thickness. At an instant close to the start of heating (15 s, left), already most of the material is above Tc1 = 370°C. After 80 s of fire application, roughly one-half of the specimen thickness has exceeded Tc2 = 370°C. That means that only one-half of the specimen thickness is not fully degraded and retains some mechanical resistance. 5.2Validation of thermal parameters at intermediate temperaturesThe set of thermal parameters proposed in the previous section have been used also to simulate the step test that previously was not correctly fitted with the room temperature parameters (Figure 3). The results are shown in Figure 15. Matching between experimental and simulated profiles is now quite good, with negligible differences, much less than 1% in K. This suggests that at least part of the larger discrepancies found in the fire tests (Figure 13 are due to phenomena not simulated by our model, such as flame fluctuations, emission of volatiles from bubbles, loss of adherence between layers, etc. 6.SUMMARY AND CONCLUSIONSA thermoplastic composite based on PAEK (Polyaryletherketone) resin has been characterized. The values of the main thermal parameters (diffusivity, conductivity, and volumetric heat capacity) have been measured at room temperature by a modified flash technique that takes into account thermal losses. Values of those parameters as a function of temperature have been proposed on the basis of experimental measurements of the evolution of temperature vs time performed on a fire test. These values have been used to feed a FEM model that uses as input the measured distribution of temperatures, as a function of time, on the face of the sample exposed to fire, and produces as output the predicted temperatures on the rear face of the sample during the fire test. Comparison of prediction and experiment has validated the proposed values of the effective thermal parameters, with differences less than 3% in K between experimental test and simulation, for temperatures up to ~ 850°C in the front face and ~ 260°C in the rear face. In step tests carried out without fire (no flame fluctuations and maximum temperature in the rear face ~ 240°C), the differences are near or below 1% in K. The proposed dependence of thermal parameters on temperature is as follows:
An appealing feature of the approach here proposed is that the internal temperature at any point of the sample can be simulated by the FEM model, providing thus a prediction of the degradation state across the specimen thickness for any time after fire application. There are, however some features found in the experimental evolution of the temperature that are not explained directly by this dependence of thermal parameters on temperature, but rather by other more complex phenomena. In particular, the fluctuations of temperature observed in the front face are probably caused by gas bubbles appearing and disappearing between specimen layers due to resin evaporation. Also, the most likely explanation of the decrease in the rear face temperature observed at the final stage of the fire test is the increase of the overall thermal resistance of the material due to loss of adherence between layers. It has been found that the material behaves very differently when steadily heated in a furnace at quasithermal equilibrium and when fire is applied on one side. While in furnace heating the thermal parameters have been found to be reversible with temperature, and almost no damage is observed up to 450 °C, when submitted to fire fire the material suffers a complete degradation of its thermal and mechanical properties at 370 “C. The difference can be explained by the large temperature gradient suffered by the material in tests performed under fire, which causes mechanical stress and accelerates degradation. This means that values of thermal properties for these materials determined in laboratory conditions may not be useful to predict their behavior when submitted to fire or high-temperature events in real conditions, and underlines the necessity of an approach based on the interplay of simulations and measurements in real fire tests. ACKNOWLEDGMENTSThis work has received funding from the Clean Sky 2 Joint Undertaking (JU) under grant agreement No 864713. The JU receives support from the European Union’s Horizon 2020 research and innovation programme and the Clean Sky 2 JU members other than the Union. It has been supported also by Comunidad de Madrid (Spain) - Multiannual agreement with UC3M (“Excelencia para el Profesorado Universitario” - EPUC3M14) - Fifth regional research plan 2016-2020. The authors wish to acknowledge also FireLab-Airbus in Getafe (Spain) for their collaboration on the fire tests. REFERENCESA. P. Mouritz and A. G. Gibson, Fire properties of polymer composite materials, 143 Springer Science & Business Media,2007). Google Scholar
Hitcomp: High temperature characterization and modelling of thermoplastic composites., Accesed,
(2019). Google Scholar
D. Parker, J. Bussink, H. T. van de Grampel, G. W. Wheatley, E.-U. Dorf, E. Ostlinning, and K. Reinking,
“Polymers, high-temperature,”
Ullmann’s encyclopedia of industrial chemistryWiley-VCH,2011). https://doi.org/10.1002/14356007.a21_449.pub2 Google Scholar
B. Ilschner, J. K. Keels, A. K. Dhingra, and R. L. McCullough,
“Composite materials,”
Ullmann’s encyclopedia of industrial chemistryWiley-VCH,2011). Google Scholar
S. Sánchez-Carballido, C. Justo-María, J. Meléndez, and F. López,
“A quantitative infrared imaging system for in situ characterization of composite materials in fire tests,”
Fire technology, 53
(3), 1309
–1331
(2017). https://doi.org/10.1007/s10694-016-0636-9 Google Scholar
C. B. Justo María,
“Caracterización térmica y de defectos en materiales compuestos mediante imagen infrarroja. Modelización física, sistema experimental y técnicas de reducción de datos.,”
Departamento de Física
(2018). Google Scholar
W. Parker, R. Jenkins, C. Butler, and G. Abbott,
“Flash method of determining thermal diffusivity, heat capacity, and thermal conductivity,”
Journal of applied physics, 32
(9), 1679
–1684
(1961). https://doi.org/10.1063/1.1728417 Google Scholar
A. Degiovanni,
“Diffusivité et methode flash,”
Rev. Gén. Therm., Fr., 32
(185), 420
–442
(1977). Google Scholar
M. Mullins, D. Liu, and H.-J. Sue,
“Mechanical properties of thermosets,”
35
–68 Thermosets: structure, properties, and applicationsElsevier,2018). Google Scholar
P. Moulinie, R. Paroli, Z. Wang, A. Delgado, A. Guen, Y. Qi, and J.-P. Gao,
“Investigating the degradation of thermoplastics by thermogravimetry-fourier transform infrared spectroscopy (tg-ftir),”
Polymer testing, 15
(1), 75
–89
(1996). https://doi.org/10.1016/0142-9418(95)00025-9 Google Scholar
S. Sánchez-Carballido, C. Justo-María, J. Meléndez, and F. López,
“Measurement of the thermal parameters of composite materials during fire tests with quantitative infrared imaging,”
Fire technology, 54
(1), 313333
(2018). https://doi.org/10.1007/s10694-017-0685-8 Google Scholar
|