Paper
13 July 2022 Comprehensive study on the difference in radiomic feature values between for-processing and for-presentation mammographic images and their discriminative power regarding BI-RADS density classification
T. Wagner, L. Cockmartin, N. Marshall, Y.K. Wang, H. Bosmans
Author Affiliations +
Proceedings Volume 12286, 16th International Workshop on Breast Imaging (IWBI2022); 1228615 (2022) https://doi.org/10.1117/12.2625776
Event: Sixteenth International Workshop on Breast Imaging, 2022, Leuven, Belgium
Abstract
Aim: To assess the difference in radiomic feature values between pairs of mammographic images used for processing(FOR PROC) and for presentation(FOR PRES) as well as the ability to determine the BIRADS density classification from these radiomic features with different classification models. Methods: A dataset of FOR PROC and FOR PRES image pairs annotated with labels for the BI-RADS classification done by a radiologist is used in this study. The differences in radiomic feature values between the image types are evaluated with the intraclass correlation coefficient(ICC). Additionally, the discriminative power of radiomic feature values regarding the BI-RADS score is evaluated with Logistic Regression, Random Forest and a 5-layer deep Neural Network. The results of these models are evaluated with a 5-fold crossvalidation. Results: The reliability of radiomic feature is generally low between pairs of FOR PROC and FOR PRES images for all radiomic feature groups. Furthermore, the simple models used to determine the ability to assign the BI-RADS density classification based on the radiomic feature values reached insufficient accuracy to be considered adequate. Conclusion: The study revealed low reliability between both image types. Furthermore radiomic features alone seem to be insufficient to determine the BI-RADS classification using simple models.
© (2022) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
T. Wagner, L. Cockmartin, N. Marshall, Y.K. Wang, and H. Bosmans "Comprehensive study on the difference in radiomic feature values between for-processing and for-presentation mammographic images and their discriminative power regarding BI-RADS density classification", Proc. SPIE 12286, 16th International Workshop on Breast Imaging (IWBI2022), 1228615 (13 July 2022); https://doi.org/10.1117/12.2625776
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Breast

Feature extraction

Reliability

Image classification

Image processing

Performance modeling

Breast cancer

Back to Top