Presentation + Paper
7 April 2023 How does image quality affect computer-aided diagnosis of colorectal polyps?
Author Affiliations +
Abstract
Colorectal cancer (CRC) is one of the leading causes of cancer-related deaths with rising incidence. Since the survival rate of CRC is correlated with the cancer stage at diagnosis, timely detection and adequate treatment strategies are of utmost importance. Technical innovations such as machine learning (ML) and its application in endoscopy show promising results, but the trust of medical doctors in ML is lacking and the ‘black box’ nature complicates the understanding of such systems in clinical practice. In contrast to CT and MRI, image quality is a limiting factor in especially endoscopic imaging, as it is very operator dependent. However, the influence of image quality on convolutional (deep) neural networks (CNNs) is insufficiently studied in relation to clinical practice and the usage of medical image data for computer-aided detection and diagnosis (CADx) systems. This paper explores the influence of degraded image quality on the performance of CNNs applied to colorectal polyp (CRP) characterization. Five commonly used CNN architectures, from simple to more complex, are employed with a custom classification head for common CRP characterization. To degrade the quality of images, distortions such as noise, blur, and contrast changes are imposed on the data and their influence on the performance degradation is studied for the mentioned CNN architectures. A large prospectively collected in vivo data set, gathered from four Dutch, both academic and community, hospitals is employed. Results for CRP characterization show that promising CNN-based methods are rather susceptible to noise and blur distortions but reasonably resilient to changes in contrast. This implies that image quality needs monitoring and control prior to directly using image data in CNN models, in order to gain trustworthy use of deep learning (DL) models in a clinical setting. We propose that incorporating an image quality indicator in CADx systems will lead to better acceptance of such systems, and is necessary for the safe implementation of DL applications in clinical practice.
Conference Presentation
© (2023) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Thom Scheeve, Nikoo Dehghani, Quirine E. W. van der Zander, Ayla Thijssen, Ramon-Michel Schreuder, Ad A. M. Masclee M.D., Erik J. Schoon, Fons van der Sommen, and Peter H. N. de With "How does image quality affect computer-aided diagnosis of colorectal polyps?", Proc. SPIE 12465, Medical Imaging 2023: Computer-Aided Diagnosis, 124650S (7 April 2023); https://doi.org/10.1117/12.2654167
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image quality

Endoscopy

Polyps

Cancer

Clinical practice

Colorectal cancer

Deep learning

Back to Top